Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JARVIS-PARIS-MURPHY COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JARVIS-PARIS-MURPHY COMPANY, INC. in 100 N. GILMER, DAWSON, TX 76639 (NAICS 424510). OSHA activity number 341318152.

Watch Jarvis-Paris-Murphy Company, INC. — free Get an email when a new federal OSHA severe-injury report for Jarvis-Paris-Murphy Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 N. GILMER
City
DAWSON
State
TX
ZIP
76639
Mailing
100 N. GILMER, DAWSON, TX 76639
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
12
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $1224.00 · Current $734.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  At the dry fertilizer mixing building, the employer did not ensure that the chain conveyor to the fertilizer leg was guarded exposing employees to caught-in hazards.
Recent events (2)
  • — I (S) $734.4
  • — Z (S) $1224

1910.219 C02 I

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $918.00 · Current $551.00 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  At the dry fertilizer mixing building, the employer did not ensure that the upper chain conveyor shaft was covered exposing employees to caught-in hazards.
Recent events (2)
  • — I (S) $550.8
  • — Z (S) $918

1910.305 B01 II

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $1530.00 · Current $918.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  In the chemical storage building, the employer did not ensure that the compressor circuit breaker panel blanks were covered exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $918
  • — Z (S) $1530

1910.305 B02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  At the chemical building, the employer did not ensure that the electrical outlet located near the air compressor was equipped with a cover exposing the employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 D01

Other-than-serious 1 instance 12 exposed
Issued
Penalty
Initial $306.00 · Current $184.00 Reduced
29 CFR 1910.23(d)(1): The employer did not provide standard railings or guards on stairways having four or more risers.  At the front of the feed and seed building, the employer did not ensure that the stairway employees used was equipped with a standard railing exposing employees to fall hazards.
Recent events (2)
  • — I (O) $183.6
  • — Z (O) $306

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341318152.