2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PEERLESS TIRES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PEERLESS TIRES in 5848 E. COUNTY LINE RD., HIGHLANDS RANCH, CO 80126 (NAICS 811111). OSHA activity number 341325678.

Watch Peerless Tires — free Get an email when a new federal OSHA severe-injury report for Peerless Tires is published. One employer, no account, unsubscribe in one click.
Establishment
PEERLESS TIRES
Site address
5848 E. COUNTY LINE RD.
City
HIGHLANDS RANCH
State
CO
ZIP
80126
Mailing
5000 KINGSTON STREET, DENVER, CO 80239
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.1200 H03 IV

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2700.00 · Current $1620.00 Reduced
29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information:   (a) On or about March 15, 2016, the employer did not effectively train employees on the data base use by their employer to access the safety data sheets.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1620
  • — Z (S) $2700

1910.157 C01

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) On or about August 27, 2015, the employer exposed employees to trip hazards due to the fire extinguishers not being mounted.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) On or about March 15, 2016, the employer did not maintain a clear distance 3 feet in front of the circuit breaker panels in that the electrical panels were not accessible preventing emergency shutdown, electrical repairs and maintenance.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341325678.