SAN ANTONIO, TX —
OSHA Inspection: JOHN L HOLCOMB INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of JOHN L HOLCOMB INC. in 11719 WARFIELD ST., SAN ANTONIO, TX 78216 (NAICS 812320). OSHA activity number 341340644.
Where did this inspection happen?
- Establishment
- JOHN L HOLCOMB INC.
- Site address
- 11719 WARFIELD ST.
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78216
- Mailing
- PO BOX 790731, SAN ANTONIO, TX 78279
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 812320
- Employees
- 14
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Chemical Storage Area: On or about March 22,2016, and times prior thereto, the employer did not establish and implement those elements of a written respiratory program, such as but not limited to medical evaluations, fit tests, or maintenance of respirators for employees who were required to wear 3M half-mask tight fitting respirators, exposing employees to undue physiological burden.
Recent events (2)
- — I (S) $500
- — Z (S) $1200
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Laundry Facility: On or about March 22, 2016, and times prior there to, employees were exposed to chemical hazards from the handling and use of corrosive chemicals, such as but not limited to, Peracid Plus 15% (Peroxyacetic Acid 15-16%), Acetic Acid 15-16%, Hydrogen Peroxide 22-23%), Dual Ultra (Sodium Hydroxide), and Power Classic (Sodium Hydroxide), and an eye wash station was not provided.
Recent events (2)
- — I (S) $500
- — Z (S) $2800
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Ironing Area: On or about March 22, 2016, and times prior thereto, employees were exposed to caught-in hazards from an in-going nip point on a Chicago Flatwork Ironer (Model G024, SN: 59499), used to iron laundry.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Ironing Area: On or about March 22, 2016 employees were exposed to electrical hazards, while using a Lasko portable fan that was fed from an extension cord routed from an outlet approximately 15-20 feet from the work station. b) Dryer Area: On or about March 22, 2016 employees were exposed to electrical hazards, while using a Lasko Shop Fan (Model NSC-243, P/N: 02030251/2010) that was fed from an extension cord routed from an outlet approximately 15 feet from the work station. c) Folding/Packaging Area: On or about March 22, 2016 employees were exposed to electrical hazards, while using a Lasko Shop Fan (Model NSC-243, P/N: 02030359R/2012) that was fed from an extension cord routed from an outlet approximately 15 feet from the work station.
Recent events (2)
- — I (S) $500
- — Z (S) $2000
1910.1030 C01 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.1030(c)(1)(i): The employer having employee(s) with occupational Bloodborne Pathogen exposure did not establish a written Exposure Control Plan designed to eliminate or minimize employee exposure: Laundry Facility: On or about March 22, 2016, and times prior thereto, the employer did not implement a written Exposure Control Plan to eliminate and minimize hazards for employees who are exposed to blood, sharps, and other potentially infectious materials while handling soiled medical laundry.
Recent events (2)
- — I (S) $500
- — Z (S) $2800
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $500.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Laundry Facility: On or about March 22, 2016, and times prior there to, employees were exposed to chemical hazards from the use and handling of chemicals, such as but not limited to Peracid Plus 15% (Peroxyacetic Acid 15-16%), Acetic Acid 15-16%, Hydrogen Peroxide 22-23%), Dual Ultra (Sodium Hydroxide), and Power Classic (Sodium Hydroxide), and the employees were not trained on the hazards associated with these chemicals.
Recent events (2)
- — I (S) $500
- — Z (S) $2800
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: Sorting area: One or about March 22, 2016, employees were exposed to fire hazards in that fire extinguishers were not clearly marked, mounted, and were blocked by large laundry bins and could not be readily accessed in the event of a fire.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: Laundry Facility: On or about March 22, 2016, and times prior there to, the company did not provide training to employees who were expected to attempt to extinguish fires in the facility using hand-held fire extinguishers in the event of a minor fire emergency.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 812320)
ADJUNTAS, PR—2026-07-09
NICK A VAZQUEZ TORRES
LAUREL, MD—2026-07-08
ZIPS CLEANERS
COLLEGE PARK, MD—2026-07-08
PASHAK CLEANERS LLC
BAYAMON, PR—2026-06-29
EDWARD MORALES MENDEZ
YAUCO, PR—2026-06-29
CUATRO CALLES DRY CLEANERS INC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341340644.