GIBSONIA, PA —
OSHA Inspection: KEANE REFRIGERATED LOGISTICS, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KEANE REFRIGERATED LOGISTICS, LLC in 24 FRONTIER DRIVE, GIBSONIA, PA 15044 (NAICS 493120). OSHA activity number 341343176.
Where did this inspection happen?
- Establishment
- KEANE REFRIGERATED LOGISTICS, LLC
- Site address
- 24 FRONTIER DRIVE
- City
- GIBSONIA
- State
- PA
- ZIP
- 15044
- Mailing
- 19420 FRAZIER DRIVE, ROCKY RIVER, OH 44116
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493120
- Employees
- 75
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.119 D03 I E
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $1875.00 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(i)(E): The employer did not have a compilation for written process safety information pertaining to the ventilation system design: a) In the facility, on or about March 23, 2016 - The employer was unable to locate or produce process safety information pertaining to the ventilation system design for the ammonia system.
Recent events (3)
- — F (S) $1875
- — C (S) $3741
- — Z (S) $3741
1910.119 D03 II
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices: a) Machine Room, on or about March 23, 2016 - The employer did not document that equipment complies with recognized and generally accepted good engineering practices (RAGAGEP) in that the ammonia machinery room was not equipped with a tight-fitting door near the rear of the machinary room. ANSI/ASHRAE Standard 15-2010, Section 8.12, Paragraph D, is an applicable RAGAGEP that describes the requirements.
Recent events (3)
- — F (S) $0
- — C (S) $3741
- — Z (S) $3741
1910.119 E01
- Issued
- Penalty
- Initial $3741.00 · Current $1875.00 Reduced
General-duty citation text
29 CFR 1910.119(e)(1): The employer did not perform an initial process hazard analysis (hazard evaluation) on processes covered by 29 CFR 1910.119: a) In the facility, on or about March 23, 2016 - The employer did not perform an initial process hazard analysis (hazard evaluation) for the facility refrigeration system utilizing anhydrous ammonia and covered by the requirements of 29 CFR 1910.119.
Recent events (3)
- — F (S) $1875
- — C (S) $3741
- — Z (S) $3741
1910.119 F01
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $1875.00 Reduced
General-duty citation text
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and addressing at least steps for each operating phase, safe operating limits, safety and health considerations, and safety systems and their functions as outlined by this paragraph: a) In the facility, on or about March 23, 2016 - The employer did not develop and implement written operating procedures for activities such as but not limited to inbounding ammonia.
Recent events (3)
- — F (S) $1875
- — C (S) $3741
- — Z (S) $3741
1910.119 F04
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations such as lockout/tagout; confined space entry; opening process equipment or piping; and control over entrance into a facility by maintenance, contractor, laboratory, or other support personnel: a) In the facility, on or about March 23, 2016 - The employer did not develop or implement specific procedures for removing oil from piping and equipment where oil is likely to collect that is specific for each drain point.
Recent events (3)
- — F (S) $0
- — C (S) $3741
- — Z (S) $3741
1910.119 J04 II
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(ii): Inspection and testing procedures did not follow recognized and generally accepted good engineering practices: a) In the facility, on or about March 23, 2016 - The company did not follow RAGAGEP, IIAR 110 Section 6.2, while conducting inspections of the ammonia system.
Recent events (3)
- — F (S) $0
- — C (S) $3741
- — Z (S) $3741
1910.119 J05
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $1875.00 Reduced
General-duty citation text
29 CFR 1910.119(j)(5): The employer did not correct deficiencies in equipment that were outside acceptable limits (defined by the process safety information on paragraph (d) of this section) before use: a) In the facility, on or about March 23, 2016 - The piping system showed evidence of external corrosion, including excessive ice build-up.
Recent events (3)
- — F (S) $1875
- — C (S) $3741
- — Z (S) $3741
1910.119 O01
- Issued
- Penalty
- Initial $3741.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.119(o)(1): The employer did not certify that they have evaluated compliance with the provisions of this section at least every three years: a) In the facility, on or about March 23, 2016 - The employer did not certify that they had evaluated compliance with the provisions of 29 CFR 1910.119 at least every three years to verify that the procedures and practices developed under the standard are adequate and are being followed.
Recent events (3)
- — F (S) $0
- — C (S) $3741
- — Z (S) $3741
More inspections in this industry (NAICS 493120)
NEWPORT, MI—2026-07-15
MEIJER DISTRIBUTION CENTER FACILITY
BIGLERVILLE, PA—2026-07-10
BREAM BEAR ORCHARDS
BIGLERVILLE, PA—2026-07-10
BREAM BEAR ORCHARDS
PLANT CITY, FL—2026-07-01
AMERICOLD LOGISTICS, LLC.
KELLER, TX—2026-07-01
KROGER TEXAS L.P.
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341343176.