PANAMA CITY, FL —
OSHA Inspection: WINTERFELL CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WINTERFELL CONSTRUCTION, INC. in 1654 E 5TH STREET, PANAMA CITY, FL 32405 (NAICS 236115). OSHA activity number 341360501.
Where did this inspection happen?
- Establishment
- WINTERFELL CONSTRUCTION, INC.
- Site address
- 1654 E 5TH STREET
- City
- PANAMA CITY
- State
- FL
- ZIP
- 32405
- Mailing
- 1204 SAVANNAH DRIVE, PANAMA CITY, FL 32405
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 1
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a. On or about March 30, 2016, while building a new commercial construction gazebo, three subcontracted employees working beneath employees installing sheets of wood sheathing to the roof area did not have protective helmets, exposing the employees to the hazard of being struck by falling objects and construction debris.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.102 A01
- Issued
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a. On or about March 30, 2016, while building a new commercial construction gazebo, subcontracted employees installing wooden roof sheathing panels and framing materials were using pneumatic nail guns and were not wearing any form of eye protection, exposing the employees to the hazard of being struck in the eye or face by flying debris.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.451 B02
- Issued
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a. On or about March 30, 2016, while building a new commercial construction gazebo, a subcontracted employee installing wood framing materials with a pneumatic nail gun was using a scaffold platform that was not at least 18 inches wide, exposing employee to a 5 foot, 9 inch fall hazard.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.451 E01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(e)(1): Where scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers, stairway-type ladders, ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used for access: a. On or about March 30, 2016, while building a new commercial construction gazebo, three subcontracted employees did not use a ladder to access or exit the top platform of a double wood pole scaffold, exposing the employees to fall hazards as high as 12 foot.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B11
- Issued
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a. On or about March 30, 2016, while building a new commercial construction gazebo, three subcontracted employees worked from a 6:12 pitched roof top of the gazebo, while exposed to fall hazards ranging from 12 to 18 feet and were not protected by any form of fall protection systems.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.1053 B04
- Issued
- Penalty
- Initial $2400.00 · Current $1680.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a. On or about March 30, 2016, while building a new commercial construction gazebo, a subcontracted employee climbed a portable, A-frame type step ladder, while the ladder was in the closed and folded position exposing the employee to slip and fall hazards to the concrete surface below.
Recent events (2)
- — I (S) $1680
- — Z (S) $2400
More inspections in this industry (NAICS 236115)
CARSON CITY, NV—2026-07-16
LT BUILDERS
FAIRVIEW, TN—2026-07-16
DRB GROUP TENNESSEE, LLC
DOVER, NH—2026-07-15
KNOX MARSH DEVELOPMENT LLC
VIENNA, VA—2026-07-15
OMARI CONSTRUCTION LLC
NORFOLK, VA—2026-07-15
SUPERIOR PRIDE INC
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341360501.