OSHA Inspection: SPENCER READY MIX

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SPENCER READY MIX in 9161 HIGHWAY 49 NORTH, JACKSON, MS 39209 (NAICS 327320). OSHA activity number 341363810.

Watch Spencer Ready MIX — free Get an email when a new federal OSHA severe-injury report for Spencer Ready MIX is published. One employer, no account, unsubscribe in one click.
Establishment
SPENCER READY MIX
Site address
9161 HIGHWAY 49 NORTH
City
JACKSON
State
MS
ZIP
39209
Mailing
9161 HIGHWAY 49 NORTH, JACKSON, MS 39209
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
20
Ownership type
A

9 citations on file for this inspection.

1910.106 D07

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1172.00 Reduced
29 CFR 1910.106(d)(7): 1910.106(d)(7): Suitable fire control devices, such as small hose or portable fire extinguihers, were not available at locations where flammable liquids are stored:     (a)    Diesel Fuel Storage Tanks - On or about March 29, 2016 the employer had not provided and mounted a portable fire extinguisher.
Recent events (2)
  • — I (S) $1172
  • — Z (S) $2000

1910.106 D07 III

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(7)(iii):  Open flames and smoking shall not be permitted in flammable liquid storage areas.  (a)  Diesel Fuel Storage Tanks - On or about March 29, 2016, open flames and smoking was as not prohibited in flammable liquid storage areas as required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 D02 II

Serious Gravity 5 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $936.00 Reduced
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water:      (a) Employee's Bathroom - On or about March 29, 2016 there was no hot water.
Recent events (2)
  • — I (S) $936
  • — Z (S) $1600

1910.141 D02 III

Serious Gravity 1 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(d)(2)(iii): Lavatories were not provided with hand soap or similar cleansing agent:   (a)    Employee's Bathroom - On or about March 29, 2016, no hand soap or cleansing agent was found in the bathroom.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 D02 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.141(d)(2)(iv): Lavatories were not provided with individual hand towels or sections thereof, of cloth or paper, warm air blowers or clean individual sections of continuous cloth toweling:   (a)     Employee's Bathroom - On or about March 29, 2016 the bathroom was not equipped with hand towels or a warm air blower or a continuous cloth toweling.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $936.00 Reduced
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:    (a)    Maintenance Shop - On or about March 29, 2016 the portable bench grinder was not equipped with an adjustable tongue guard.
Recent events (2)
  • — I (S) $936
  • — Z (S) $1600

1910.253 B04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $936.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:      (a)    Maintenance Shop - On or about March 29, 2016 oxygen and acetylene cylinders were stored together.
Recent events (2)
  • — I (S) $936
  • — Z (S) $1600

1910.147 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a)    Plant Wide - On or about March 29, 2016 the employer had not established a written Lockout/Tagout program.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:      (a)    Work Area - On or about March 29, 2016 the employer has not established or implemented a written Hazard Communication Program.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341363810.