Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NORTH TEXAS HEATING AND AIR CONDITIONING, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of NORTH TEXAS HEATING AND AIR CONDITIONING, INC. in 7000 VASSAR AVENUE, DALLAS, TX 75205 (NAICS 238220). OSHA activity number 341385466.

Watch North Texas Heating AND AIR Conditioning, INC. — free Get an email when a new federal OSHA severe-injury report for North Texas Heating AND AIR Conditioning, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7000 VASSAR AVENUE
City
DALLAS
State
TX
ZIP
75205
Mailing
PO BOX 23, ARGYLE, TX 76226
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $4200.00 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    (a) On or about April 7, 2016, in the attic, employees who were installing HVAC equipment and working in close proximity to electrical wiring were exposed to an electrical hazard.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1926.1203 A

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1203(a): Before it began work at a worksite, the employer did not ensure that a competent person identified all confined spaces in which one or more of the employees it directed may have worked, and/or did not identify each space that was a permit space, through consideration and evaluation of the elements of that space, including testing as necessary:  On or about April 7, 2016, the employer did not identify a crawl space in the attic as a permit space.  Employees working in the space were exposed to an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $996.00 Reduced
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers:     (a) On or about April 7, 2016, in the attic, employees who were installing HVAC equipment.
Recent events (2)
  • — I (O) $996
  • — Z (S) $2000

1904.39 A01

Deleted Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1904.39(a)(1): The employer did not report within 8-hours the death of an employee resulting from a work-related incident:   The employer did not make an oral report to OSHA within eight hours after the death of an employee from a work-related incident that occurred on April 7, 2016.
Recent events (2)
  • — I (O) $0
  • — Z (O) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341385466.