Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOUTHCROSS ENERGY GP, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SOUTHCROSS ENERGY GP, LLC in 224 LEVEIN ROAD, WOODSBORO, TX 78393 (NAICS 237120). OSHA activity number 341391639.

Watch Southcross Energy GP, LLC — free Get an email when a new federal OSHA severe-injury report for Southcross Energy GP, LLC is published. One employer, no account, unsubscribe in one click.
Site address
224 LEVEIN ROAD
City
WOODSBORO
State
TX
ZIP
78393
Mailing
P O BOX 1255, WOODSBORO, TX 78393
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237120
Employees
300
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $12471.00 · Current $0.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards associated with unexpected release of hazardous energy.   At the workplace, an employee conducted hot tap operations on a pressurized gas pipeline. The employer did not evaluate the work to determine if isolation and de-energization of the system was feasible, and/or did not document, implement, and/or follow procedures to control the unexpected release of hazardous energy. This exposed the employee to struck-by and other hazards associated with a high pressure gas release.
Recent events (3)
  • — F (S) $0
  • — C (S) $12471
  • — Z (S) $12471

1926.21 B02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $12471.00 · Current $12471.00
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury.     At this workplace, an employee conducted hot-tap operations in an excavation greater than five feet in depth and were not adequately instructed in the recognition and avoidance of excavation engulfment hazards.  The employee was exposed to struck-by and engulfment hazards.
Recent events (3)
  • — F (O) $12471
  • — C (S) $12471
  • — Z (S) $12471

1926.651 C02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $12471.00 · Current $12471.00
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:      At this workplace, an employee conducted hot-tap operations in an excavation greater than five feet in depth and approximately forth-five feet in length and did not have a safe means of egress in that; the hot tap tool was obstructing  the route of egress.  The employee was exposed to engulfment and struck-by hazards.
Recent events (3)
  • — F (O) $12471
  • — C (S) $12471
  • — Z (S) $12471

1926.652 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $12471.00 · Current $0.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).   At this workplace, an employee conducted hot-tap operations in an excavation greater than five feet in depth.  Designs for benching were not in accordance with tabulated data, to ensure excavation protective systems were safe for employee entry. The employee was exposed to engulfment and struck-by hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $12471
  • — Z (S) $12471

1926.651 K01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $12471.00
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems.      At this workplace, employees conducted hot-tap operations in an excavation greater than five feet in depth, daily inspections were not conducted by a competent person to ensure the excavation protective systems were in place for employee safety.  The employees were exposed to engulfment and struck-by hazards.
Recent events (3)
  • — F (S) $12471
  • — C (S) $0
  • — Z (S) $0

View SOUTHCROSS ENERGY GP, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341391639.