On , OSHA opened a federal Agency safety inspection of SOUTHCROSS ENERGY GP, LLC in 224 LEVEIN ROAD, WOODSBORO, TX 78393 (NAICS 237120). OSHA activity number 341391639.
Where did this inspection happen?
- Establishment
- SOUTHCROSS ENERGY GP, LLC
- Site address
- 224 LEVEIN ROAD
- City
- WOODSBORO
- State
- TX
- ZIP
- 78393
- Mailing
- P O BOX 1255, WOODSBORO, TX 78393
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237120
- Employees
- 300
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Penalty
- Initial $12471.00 · Current $0.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards associated with unexpected release of hazardous energy. At the workplace, an employee conducted hot tap operations on a pressurized gas pipeline. The employer did not evaluate the work to determine if isolation and de-energization of the system was feasible, and/or did not document, implement, and/or follow procedures to control the unexpected release of hazardous energy. This exposed the employee to struck-by and other hazards associated with a high pressure gas release.
Recent events (3)
- — F (S) $0
- — C (S) $12471
- — Z (S) $12471
1926.21 B02
- Issued
- Penalty
- Initial $12471.00 · Current $12471.00
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury. At this workplace, an employee conducted hot-tap operations in an excavation greater than five feet in depth and were not adequately instructed in the recognition and avoidance of excavation engulfment hazards. The employee was exposed to struck-by and engulfment hazards.
Recent events (3)
- — F (O) $12471
- — C (S) $12471
- — Z (S) $12471
1926.651 C02
- Issued
- Penalty
- Initial $12471.00 · Current $12471.00
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: At this workplace, an employee conducted hot-tap operations in an excavation greater than five feet in depth and approximately forth-five feet in length and did not have a safe means of egress in that; the hot tap tool was obstructing the route of egress. The employee was exposed to engulfment and struck-by hazards.
Recent events (3)
- — F (O) $12471
- — C (S) $12471
- — Z (S) $12471
1926.652 A01
- Issued
- Penalty
- Initial $12471.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). At this workplace, an employee conducted hot-tap operations in an excavation greater than five feet in depth. Designs for benching were not in accordance with tabulated data, to ensure excavation protective systems were safe for employee entry. The employee was exposed to engulfment and struck-by hazards.
Recent events (3)
- — F (S) $0
- — C (S) $12471
- — Z (S) $12471
1926.651 K01
- Issued
- Penalty
- Initial $0.00 · Current $12471.00
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems. At this workplace, employees conducted hot-tap operations in an excavation greater than five feet in depth, daily inspections were not conducted by a competent person to ensure the excavation protective systems were in place for employee safety. The employees were exposed to engulfment and struck-by hazards.
Recent events (3)
- — F (S) $12471
- — C (S) $0
- — Z (S) $0
More inspections at SOUTHCROSS ENERGY GP, LLC
GREGORY, TX—2011-06-20 00:00:00
SOUTHCROSS ENERGY GP LLC
View SOUTHCROSS ENERGY GP, LLC's full OSHA safety record →
More inspections in this industry (NAICS 237120)
ARCADIA, FL—2026-07-14
M. G. DYESS, LLC
ODEM, TX—2026-07-09
MPG PIPELINE CONTRACTORS, LLC
FREMONT, MI—2026-07-07
ROESE PIPELINE COMPANY, INC.
BROOK PARK, OH—2026-06-30
MICHELS FOUNDATIONS - FRANKSVILLE, A DIVISION OF MICHELS CONSTRUCTION, INC.
HAZLE TOWNSHIP, PA—2026-06-24
LINDE CORPORATION
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341391639.