Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WHITE SWAN MOTEL, LLC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of WHITE SWAN MOTEL, LLC. in 6060 W. COLFAX AVENUE, LAKEWOOD, CO 80226 (NAICS 721110). OSHA activity number 341395051.

Watch White Swan Motel, LLC. — free Get an email when a new federal OSHA severe-injury report for White Swan Motel, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
6060 W. COLFAX AVENUE
City
LAKEWOOD
State
CO
ZIP
80226
Mailing
6060 W. COLFAX AVE, LAKEWOOD, CO 80214
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1700.00 · Current $1020.00 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  (a) On or about April 13, 2016, and at times prior, White Swan Motel, LLC., did not ensure that ground fault circuit interrupters, or an assured equipment grounding conductor program was used to protect its employees at a renovation project. Employees were exposed to contact with electrical hazards, in that a 120V temporary wiring branch was connected directly to a utility service drop, without ground fault circuit interrupters, or an assured grounding conductor program.   Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1700

1926.405 A02 II B

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(B): Temporary wiring branch circuits did not originate in a power outlet or panel board, and were not protected by over current devices:   (a) On or about April 13, 2016, and at times prior, White Swan Motel, LLC., did not ensure that temporary wiring branch circuits originated in a power outlet or panel board, and was protected by over current devices. Employees were exposed to contact with electrical hazards, in that a 120V temporary wiring branch was connected directly to a utility service drop. The ~250 feet-long temporary wiring branch did not originate on a power outlet or a  panel board, and was not protected by over current devices.  Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:  (a) On or about April 13, 2016, and at times prior, White Swan Motel, LLC., did not ensure that flexible cords were used in continuous lengths without splice or tap. Employees were exposed to contact with electrical hazards, in that a spliced flexible cord was used to power temporary lighting while renovating rooms after fire damage.  Abatement Note: Abatement certification is not required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341395051.