Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WAUPACA FOUNDRY LAWRENCEVILLE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WAUPACA FOUNDRY LAWRENCEVILLE in 18986 ROUTE 287, LAWRENCEVILLE, PA 16929 (NAICS 331511). OSHA activity number 341413870.

Watch Waupaca Foundry Lawrenceville — free Get an email when a new federal OSHA severe-injury report for Waupaca Foundry Lawrenceville is published. One employer, no account, unsubscribe in one click.
Site address
18986 ROUTE 287
City
LAWRENCEVILLE
State
PA
ZIP
16929
Mailing
18986 ROUTE 287, LAWRENCEVILLE, PA 16929
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
260
Ownership type
A

3 citations on file for this inspection.

1910.27 D01 V

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2250.00 · Current $1350.00 Reduced
29 CFR 1910.27(d)(1)(v): Vertical bars on the fixed ladder safety cage were not located at a maximum spacing of 40 degrees around the circumference of the cage giving a maximum spacing of approximately 9 1/2 inches, center to center:    a) Sand Silo #1: Vertical safety bars were missing between the second and third horizontal rings exposing employees to a potential 15-20 foot fall hazard, as observed on or about April 20, 2016.    Abatement Certification Required.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $2250

1910.27 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.27(b)(2): Side rails that could be used as a climbing aid were not of such cross sections as to afford adequate gripping surface without sharp edges, splinters, or burrs:  a) Sand silo #1: Electrical conduit was attached to the left side rail thus not affording an adequate grip and sharp edges were created where side rails were spliced together, as observed on or about April 20, 2016.  Abatement Certification Required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 A04

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  a) Emergency exit, near time clock: The fire door latch mechanism was not in proper working order to hold the fire door in the closed position, as observed on or about April 20, 2016.  Abatement Certification Required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341413870.