LAWRENCEVILLE, PA —
OSHA Inspection: WAUPACA FOUNDRY LAWRENCEVILLE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WAUPACA FOUNDRY LAWRENCEVILLE in 18986 ROUTE 287, LAWRENCEVILLE, PA 16929 (NAICS 331511). OSHA activity number 341413870.
Where did this inspection happen?
- Establishment
- WAUPACA FOUNDRY LAWRENCEVILLE
- Site address
- 18986 ROUTE 287
- City
- LAWRENCEVILLE
- State
- PA
- ZIP
- 16929
- Mailing
- 18986 ROUTE 287, LAWRENCEVILLE, PA 16929
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331511
- Employees
- 260
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.27 D01 V
- Issued
- Abate by
- Penalty
- Initial $2250.00 · Current $1350.00 Reduced
General-duty citation text
29 CFR 1910.27(d)(1)(v): Vertical bars on the fixed ladder safety cage were not located at a maximum spacing of 40 degrees around the circumference of the cage giving a maximum spacing of approximately 9 1/2 inches, center to center: a) Sand Silo #1: Vertical safety bars were missing between the second and third horizontal rings exposing employees to a potential 15-20 foot fall hazard, as observed on or about April 20, 2016. Abatement Certification Required.
Recent events (2)
- — I (S) $1350
- — Z (S) $2250
1910.27 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.27(b)(2): Side rails that could be used as a climbing aid were not of such cross sections as to afford adequate gripping surface without sharp edges, splinters, or burrs: a) Sand silo #1: Electrical conduit was attached to the left side rail thus not affording an adequate grip and sharp edges were created where side rails were spliced together, as observed on or about April 20, 2016. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 A04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a) Emergency exit, near time clock: The fire door latch mechanism was not in proper working order to hold the fire door in the closed position, as observed on or about April 20, 2016. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 331511)
CORNWALL, PA—2026-07-01
PRL INDUSTRIES INC
CORNWALL, PA—2026-07-01
PRL INDUSTRIES INC
EASTON, PA—2026-07-01
VICTAULIC COMPANY
HAMBURG, PA—2026-06-18
HAMBURG PLOW WORKS, INC.
EADS, TN—2026-06-17
JACKIE CARROLL
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source