Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARS R US

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CARS R US in 1170 UPPER FRONT ST, BINGHAMTON, NY 13905 (NAICS 441120). OSHA activity number 341422822.

Watch Cars R US — free Get an email when a new federal OSHA severe-injury report for Cars R US is published. One employer, no account, unsubscribe in one click.
Establishment
CARS R US
Site address
1170 UPPER FRONT ST
City
BINGHAMTON
State
NY
ZIP
13905
Mailing
1170 UPPER FRONT ST, BINGHAMTON, NY 13905
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441120
Employees
2
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards.  a) 1170 Upper Front St, Binghamton NY, 13905, Vehicle Lift (Model BP7), On or about 4/21/16: A vehicle lift  was not inspected in accordance with ANSI/ALI ALOIM 2008-Standards for Automotive Lifts-Safety Requirements for Operation, Inspection and Maintenance.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07

Serious Gravity 5 4 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner.  a) 1170 Upper Front St, Binghamton, NY 13905, Repair bays, On or about 4/21/16:  Electrical equipment throughout the building was not installed in a workmanlike manner in that flexible wiring powering 110 outlets, lighting circuits and portable power tools was either not attached to surface walls, were  run through pinch points, or not properly enclosed or encased.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i).    a) 1120 Upper Front  St, Binghamton, NY - Repair Bay hallway, On or about 4/21/16: A panel box has open circuit breaker slots exposing employees to live electrical parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $0.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.      a) 1170 Upper Front St, Binghamton, NY 13905, On or about 4/21/16:  The employer had not developed, implemented nor trained his employees in the hazards of  chemicals,  used during car repair work, such as brakekleen brake cleaner, penetrant oils and other solvents.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1910.1200 H01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area.  a) 1170 Upper Front St, Binghamton, NY 13905, On or about 4/21/16: The employer did not provide effective information and training on hazardous chemicals used during car repairs at the time of initial assignment or when new chemicals were introduced.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 A03

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.253(a)(3): Apparatus such as torches, regulators or pressure-reducing valves, acetylene generators, and manifolds used in an oxygen-fuel gas system had not been approved.    a) 1170 Upper Front St, Binghamton, NY 13905, Repair Bay, On or about 4/21/16: A fuel  gas welding regulator was missing a lens cover.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B01 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed.  a) 1170 Upper Front St, Binghamton, NY, 13905, Repair bay hallway,  On or about 4/21/16: A  3 inch knockout was missing on the main knife switch panel box.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose.   a) 1170 Upper Front St, Binghamton, NY, Repair bays, On or about 4/21/16: Junction boxes were missing proper covers.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

CARS R US