SPENCER, MA —
OSHA Inspection: HUANG MJ CONSTRUCTION INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HUANG MJ CONSTRUCTION INC in 53 CHESTNUT ST, SPENCER, MA 01562 (NAICS 238160). OSHA activity number 341424927.
Where did this inspection happen?
- Establishment
- HUANG MJ CONSTRUCTION INC
- Site address
- 53 CHESTNUT ST
- City
- SPENCER
- State
- MA
- ZIP
- 01562
- Mailing
- 69 APPLETON ST, NORTH QUINCY, MA 02171
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.304 H01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded: a) 53 Chestnut St., Spencer, MA: On or about April 15, 2016, employees were using a DeWalt brand 10 inch portable table saw without any guard on the blade to cut dimensional lumber for their work functions. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.403 B02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, and/or certified equipment was not installed and/or used in accordance with instructions included in the listing, labeling, and/or certification: a) 53 Chestnut St., Spencer, MA: On or about April 15, 2016, employees were using power tools that were powered through extension cords that were plugged into another extension cord to extend the reach of the extension cords, which is prohibited by the manufacturer and listed as prohibited on the labels attached to these cords. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) 53 Chestnut St., Spencer, MA: On or about April 15, 2016, an employee was working from a pump jack scaffold at this residence more than 30 feet above the ground below without any fall protection. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: a) 53 Chestnut St., Spencer, MA: On or about April 15, 2016, the pump jack scaffold in use at this location was not secured in any fashion at the bottom of any of the support poles for the scaffold system. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.501 B04 I
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a) 53 Chestnut St., Spencer, MA: On or about April 15, 2016, employees were working adjacent to multiple, large floor holes to rebuild this residence more than 10 feet above the next,lower floor without any covers or protection to prevent the employees from falling through those holes. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.501 B13
- Issued
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) 53 Chestnut St., Spencer, MA: On or about April 15, 2016, an employee was roofing this residence more than 25 feet above the ground below without any fall protection. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were not used only for the purpose for which they were designed: a) 53 Chestnut St., Spencer, MA: On or about April 15, 2016, an employee was observed climbing down an unopened A frame ladder to exit his roof top work location which is prohibited by the manufacturer in the directions printed on this ladder. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341424927.