CARTERET, NJ —
OSHA Inspection: ROCA TILE USA, INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ROCA TILE USA, INC in 8001 INDUSTRIAL HIGHWAY, CARTERET, NJ 07008 (NAICS 314129). OSHA activity number 341433308.
Where did this inspection happen?
- Establishment
- ROCA TILE USA, INC
- Site address
- 8001 INDUSTRIAL HIGHWAY
- City
- CARTERET
- State
- NJ
- ZIP
- 07008
- Mailing
- 8001 INDUSTRIAL HIGHWAY, CARTERET, NJ 07008
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 314129
- Employees
- 7
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $6414.00 · Current $4170.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer had not developed or implemented a written hazard communication program which describes how the criteria in 29 CFR 1910.1200 (f), (g), and (h) will be met: Roca Tile USA, Inc / NJ site: The employer did not develop nor implement a written hazard communication program for employees who are exposed to chemicals including, but not limited to 4'4-Diphenylmethane Diisocyanate (MDI) contained in Smart Foam A and Smart Lube which are used during foam packaging operations. Condition observed on/or about 4/28/2016.
Recent events (2)
- — I (S) $4170
- — Z (S) $6414
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employers were not provided information and training as specified in 29 CFR 1910.1200(h)(2) and (3) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area: Roca Tile USA, Inc/ NJ site: The employer did not train employees who are exposed to chemicals including, but not limited to 4'4-Diphenylmethane Diisocyanate (MDI) contained in Smart Foam A and Smart Lube. Condition observed on/or about 04/28/2016.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at ROCA TILE USA, INC
CARTERET, NJ—2023-12-12 00:00:00
ROCA TILE USA, INC
MIAMI, FL—2023-11-14 00:00:00
ROCA TILE USA, INC.
View ROCA TILE USA, INC's full OSHA safety record →
More inspections in this industry (NAICS 314129)
AUBURN, WA—2025-08-06
WA317987256 - WEST COAST TEXTILES LLC
HENDERSONVILLE, NC—2025-01-16
158120 - HARDIN MANUFACTURING CO.
CONOVER, NC—2024-11-21
157853 - PREMIUM CUSHION, INC.
AUBURN, WA—2024-09-17 00:00:00
WA317982281 - WEST COAST TEXTILES LLC
HENDERSON, NC—2024-07-16 00:00:00
157092 - BEDDING ACQUISTION, LLC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source