Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WILLIAM DOUGHERTY MASONRY CONTRACTOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WILLIAM DOUGHERTY MASONRY CONTRACTOR in 440 WEST KIRKPATRICK STREET, SYRACUSE, NY 13205 (NAICS 238140). OSHA activity number 341460871.

Watch William Dougherty Masonry Contractor — free Get an email when a new federal OSHA severe-injury report for William Dougherty Masonry Contractor is published. One employer, no account, unsubscribe in one click.
Site address
440 WEST KIRKPATRICK STREET
City
SYRACUSE
State
NY
ZIP
13205
Mailing
3777 EAST ROAD, CAZENOVIA, NY 13035
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $313.00 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used:    a) On or about 5/5/16, At the job site:  Employees were accessing the top (third) level of the tubular welded frame scaffold, which had a distance of twenty feet to the ground and 6.66 feet to the second level.  There was no ladder or safe means of access provided.     Abatement certification is required for this item.
Recent events (3)
  • — J (S) $313
  • — C (S) $2000
  • — Z (S) $2000

1926.1051 A

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:  a) On or about 5/5/16, At the job site:  Employees were accessing the outrigger portion of the tubular welded frame scaffold via window sills that were approximately three feet above the second floor of the building.  No access was provided between the sill and floor of the building.   Abatement certification is required for this item.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.451 G01 VI

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $438.00 Reduced
29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity):    a) On or about 5/5/16, At the job site:  Employees were utilizing a tubular welded frame scaffold system that was three bays wide and three stages high.  Employees were working off of the top level of the scaffolding system which was not provided with any fall protection, and were working off of the second level which was provided with cross bracing on two of the three bays.  Employees were exposed to falls of up to twenty feet.      Abatement documentation is required for this item.
Recent events (3)
  • — J (S) $438
  • — C (S) $2800
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $250.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed    a) On or about 5/5/16, At the job site:  Employees were accessing the second level of the tubular welded frame scaffold with an extension ladder that only extended approximately one foot past the landing surface.     Abatement certification is required for this item.
Recent events (3)
  • — J (S) $250
  • — C (S) $1600
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341460871.