DUBLIN, PA —
OSHA Inspection: PREMIER ONE BUILDING SERVICES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PREMIER ONE BUILDING SERVICES in 106 DUBLIN PROFESSIONAL BLDG. MARKET AND ROUTE 313, DUBLIN, PA 18917 (NAICS 236116). OSHA activity number 341469666.
Where did this inspection happen?
- Establishment
- PREMIER ONE BUILDING SERVICES
- Site address
- 106 DUBLIN PROFESSIONAL BLDG. MARKET AND ROUTE 313
- City
- DUBLIN
- State
- PA
- ZIP
- 18917
- Mailing
- 1025 QUINTON AVE., TRENTON, NJ 08629
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 601 Dublin Professional Bldg. - On or about May 12, 2016, employees engaged in residential roofing work, approximately 25 feet above grade, were not utilizing any means of fall protection.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1960.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 106 Dublin Professional Bldg. - On or about May 12, 2016, employees are utilizing a ladder to access the roof that is not extended at least 3 feet above the upper landing surface.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1926.1053 B05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support): a) 106 Dublin Professional Bldg. - On or about May 12, 2016, an extension ladder used by employees to access the roof was set at an angle such that the horizontal distance from the top support to the foot of the ladder was in excess of one-quarter of the working length of the ladder.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236116)
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
NEWTON, MA—2026-07-14
DELLBROOK CONSTRUCTION, LLC
NEWTON, MA—2026-07-14
GARDEN HOMES
PLAIN CITY, OH—2026-07-09
RUSCILLI CONSTRUCTION
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341469666.