1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: EQ FLORIDA INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of EQ FLORIDA INC. in 7202 EAST EIGHTH AVE., TAMPA, FL 33619 (NAICS 562910). OSHA activity number 341492726.

Watch EQ Florida INC. — free Get an email when a new federal OSHA severe-injury report for EQ Florida INC. is published. One employer, no account, unsubscribe in one click.
Establishment
EQ FLORIDA INC.
Site address
7202 EAST EIGHTH AVE.
City
TAMPA
State
FL
ZIP
33619
Mailing
7202 EAST EIGHTH AVE., TAMPA, FL 33619
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
70
Ownership type
A

2 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  (a) At Tampa Electric Power Plant, SR 37, Mulberry, FL 33860. Employees were checking/purging the valve on the vac tanker after the initial cleaning that originally carried sulfuric acid (93%) without wearing chemical protective pants and was splashed by the sulfuric acid that was left in the valve. This resulted in one of the employee suffering chemical burns on his left thigh and he had to be hospitalized on or about 04/01/2016.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.132 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:  (a) At Tampa Electric Power Plant, SR 37, Mulberry, FL 33860. Employees were checking/purging the valve on the vac tanker after the initial cleaning that originally carried sulfuric acid (93%) without employer assessing that there is a potential of a splash hazard from sulfuric acid that remained in the valve. This resulted in one of the employee suffering chemical burns on his left thigh and he had to be hospitalized on or about 04/01/2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View EQ FLORIDA INC.'s full OSHA safety record →