HUNTINGDON VALLEY, PA —
OSHA Inspection: SOUTHBROOK MASONRY, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of SOUTHBROOK MASONRY, LLC in 2085 LIEBERMAN DR., HUNTINGDON VALLEY, PA 19006 (NAICS 238140). OSHA activity number 341498145.
Where did this inspection happen?
- Establishment
- SOUTHBROOK MASONRY, LLC
- Site address
- 2085 LIEBERMAN DR.
- City
- HUNTINGDON VALLEY
- State
- PA
- ZIP
- 19006
- Mailing
- P.O. BOX 1703, SOUTHAMPTON, PA 18966
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 15
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $1600.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform. a) Scaffolding: On or about May 18, 2016, employees used tubular welded frame scaffolding that was not fully planked between its uprights.
Recent events (2)
- — I (S) $0
- — Z (S) $1600
1926.451 C03
- Issued
- Penalty
- Initial $0.00 · Current $400.00
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights were not plumb and braced to prevent swaying and displacement. a) Scaffolding: On or about May 18, 2016, employees were using a tubular welded frame scaffold with missing crossbracing on the interior of the second section, which does not ensure the scaffold remains plumb while under load.
Recent events (2)
- — I (O) $400
- — Z (S) $0
1926.451 E01
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Scaffolding: On or about May 18, 2016, employees are using a tubular welded frame scaffold which does not have an integral climbing frame to access two sections of scaffolding.
Recent events (2)
- — I (S) $1600
- — Z (S) $1600
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source