Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JULIO SALCEDO VEGA

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of JULIO SALCEDO VEGA in 296 ANDALUSIA AVE, CORAL GABLES, FL 33134 (NAICS 811192). OSHA activity number 341508059.

Watch Julio Salcedo Vega — free Get an email when a new federal OSHA severe-injury report for Julio Salcedo Vega is published. One employer, no account, unsubscribe in one click.
Establishment
JULIO SALCEDO VEGA
Site address
296 ANDALUSIA AVE
City
CORAL GABLES
State
FL
ZIP
33134
Mailing
108 SW 38 COURT, MIAMI, FL 33144
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811192
Employees
2
Ownership type
A

5 citations on file for this inspection.

1910.169 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.169(b)(2): Air receiver(s) were not drained frequently and at such intervals as to prevent excess accumulation of water:  On or about 05/28/2016, at 296 Andalusia Avenue, in Coral Gables, Florida, an employee was exposed to an explosion hazard due to air receivers were not drained frequently to prevent excess accumulation of water.
Recent events (1)
  • — Z (S) $0

1910.169 B03 I

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.169(b)(3)(i): Air receivers were not equipped with were not equipped with one or more spring-loaded safety valves to prevent pressure in the receiver from exceeding the maximum allowable working pressure of the receiver by more than 10 percent:  On or about 05/28/2016, at 296 Andalusia Avenue, in Coral Gables, Florida, an employee was exposed to a struck-by hazard due to air receivers were not equipped with a spring-loaded safety valve.
Recent events (1)
  • — Z (S) $0

1910.304 F01 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:  On or about 05/28/2016, at the above addressed worksite, overcurrent devices were not readily accessible to each employee or authorized building management personnel.
Recent events (1)
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug-connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation):  On or about 05/28/2016, at the above addressed worksite, an employee was exposed to a shock hazard from an electrical plug on a vacuum cleaner that was missing a ground pin.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met  On or about 05/28/2016, at the above addressed worksite, the employer did not develop, implement, and maintain at each workplace, a written hazard communication program for employees using degreaser which at least describes how the criteria specified in paragraph (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341508059.