VICTOR, NY —
OSHA Inspection: DMC FACILITY SERVICES, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DMC FACILITY SERVICES, LLC in PF CHANG'S CHINA BISTRO, 820 EASTVIEW MALL, VICTOR, NY 14564 (NAICS 561790). OSHA activity number 341537710.
Where did this inspection happen?
- Establishment
- DMC FACILITY SERVICES, LLC
- Site address
- PF CHANG'S CHINA BISTRO, 820 EASTVIEW MALL
- City
- VICTOR
- State
- NY
- ZIP
- 14564
- Mailing
- 2030 SPRINGDALE ROAD, CHERRY HILL, NJ 08003
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561790
- Employees
- 30
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $6236.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) Entire work site, on or about 5-23-16: Three employees were working without the training necessary to recognize the hazards associated with their work. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $6236
1926.300 B01
- Issued
- Penalty
- Initial $6236.00 · Current $4279.00 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) North end of building, on or about 5-23-16: One employee was cutting steel using a portable, hand-held electric angle grinder that was not equipped with a protective guard.
Recent events (2)
- — I (S) $4279
- — Z (S) $6236
1926.404 B01 II
- Issued
- Penalty
- Initial $4988.00 · Current $3481.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) Northwest corner of building, on or about 5-23-16: One employee was operating a hand held portable grinder that was not protected by a ground fault circuit interrupter (GFCI).
Recent events (2)
- — I (S) $3481
- — Z (S) $4988
1926.405 A02 II I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points: a) Northwest corner of building, on or about 5-23-16: One employee was operating a hand held portable grinder, powered by a cord that was routed beneath a closed door, subjecting the cord to damage.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Penalty
- Initial $8730.00 · Current $13159.00
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) East side of building, on or about 5-23-16: One employee was painting while standing on a trellis canopy, without fall protection, exposing the employee to a fall hazard of 11 feet 3 inches. b) North side of building, on or about 5-23-16: One employee was dismantling a steel grate canopy, without fall protection, exposing the employee to a fall hazard of 12 feet 1 inches.
Recent events (2)
- — I (S) $13159
- — Z (S) $8730
1926.1053 B04
- Issued
- Penalty
- Initial $3741.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) East side of building, on or about 5-23-16: One employee was painting while using a step ladder that was not being used as designed or for its intended purpose, in that it was leaning against a wall.
Recent events (2)
- — I (S) $0
- — Z (S) $3741
1926.1053 B05 I
- Issued
- Penalty
- Initial $4988.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a) North end of building, on or about 5-23-16: One employee was using a portable extension ladder that was set with a horizontal distance more than ¼ of the working length of the ladder (4:1), exposing the employee to a fall hazard of 12 feet 1 inch.
Recent events (2)
- — I (S) $0
- — Z (S) $4988
More inspections in this industry (NAICS 561790)
EAU CLAIRE, WI—2026-07-10
MIDWEST POWER WASHING, LLC
TUCSON, AZ—2026-07-08
CPX2026XSS813X0009 - SKYTEK BUILDING SERVICES, L.L.C.
ROANOKE, VA—2026-07-07
UNDER ONE ROOF HOME LIQUIDATION AND ESTATE SERVICES, INC.
BREMERTON, WA—2026-07-02
WA317991921 - KITSAP POWER WASH LLC
EVERETT, WA—2026-07-01
WA317991922 - NATIONAL FACILITY CONTRACTORS LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341537710.