COLORADO SPRINGS, CO —
OSHA Inspection: SUPERIOR AUTOMOTIVE & RV REPAIR
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SUPERIOR AUTOMOTIVE & RV REPAIR in 1839 DUBLIN BLVD., COLORADO SPRINGS, CO 80918 (NAICS 811111). OSHA activity number 341539930.
Where did this inspection happen?
- Establishment
- SUPERIOR AUTOMOTIVE & RV REPAIR
- Site address
- 1839 DUBLIN BLVD.
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80918
- Mailing
- 1839 DUBLIN BLVD., COLORADO SPRINGS, CO 80918
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.1200 H03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: (a) On or about June 10, 2016, the employer did not train employees on the hazard communication program use by their employer to access the safety data sheets. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) On or about June 29, 2016, and at times prior, the employees were exposed to electrical hazards in the shop area while operating the parts wash machine where as the cord connected to the electrical junction did not have adequate strain relief. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) On or about June 10, 2016, the employer exposed employees to stuck-by and caught-in hazards due to the bench grinders missing the work rest and not being adjusted to one eight inch. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.215 A03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(a)(3): Grinding machine(s) were not equipped with flanges in accordance with 29 CFR 1910.215(c): (a) On or about June 10, 2016, the employer exposed employees to stuck-by hazards due to the bench grinders, located in the shop area was missing outer flange. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) On or about June 10, 2016, the employer exposed employees to stuck-by and caught-in hazards due to the bench grinders missing the tongue guards and not being adjusted to one fourth inch. Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (S) $0
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about June 10, 2016, the employer did not maintain a clear distance 3 feet in front of the circuit breaker panels in that the electrical panels were not accessible preventing emergency shutdown, electrical repairs and maintenance. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 811111)
LONGVIEW, WA—2026-07-09
WA317992006 - LONGVIEW AUTO REPAIR LLC
HOUGHTON LAKE, MI—2026-07-08
WILSON'S AUTOMOTIVE
KELSO, WA—2026-07-08
WA317991989 - THOMAS TRANSMISSIONS LLC
BURTON, MI—2026-07-07
AMERICA'S MOST WANTED 4X4
FISHERS, IN—2026-07-07
PEP BOYS AUTO SERVICE & TIRES
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341539930.