OSHA Inspection: TRIUMPH AIRBORNE STRUCTURES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TRIUMPH AIRBORNE STRUCTURES, INC. in 115 CENTENNIAL DRIVE, HOT SPRINGS, AR 71913 (NAICS 336413). OSHA activity number 341547628.

Watch Triumph Airborne Structures, INC. — free Get an email when a new federal OSHA severe-injury report for Triumph Airborne Structures, INC. is published. One employer, no account, unsubscribe in one click.
Site address
115 CENTENNIAL DRIVE
City
HOT SPRINGS
State
AR
ZIP
71913
Mailing
115 CENTENNIAL DRIVE, HOT SPRINGS, AR 71913
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
170
Ownership type
A

1 citation on file for this inspection.

1910.1026 J01 I

Deleted Serious Gravity 10 1 instance 36 exposed
Issued
Abate by
Penalty
Initial $12471.00 · Current $0.00 Reduced
29 CFR 1910.1026(j)(1)(i): The employer did not ensure that all surfaces were maintained as free as practicable of accumulations of chromium (VI):  On or about August 23, 2016 and at times prior thereto, in the change room, for employees sanding and buffing on air craft parts, the employer's own daily and weekly end-of-shift housekeeping practices in areas which are routinely cleaned did not effectively provide employees who were not protected by personal protective equipment with clean surface areas beyond the regulated areas that were free from Chromium (VI) contamination.  This condition exposed the employees to allergic skin dermatitis hazards.   Table 1. Wipe Samples, Triumph Airborne Structures, Inc. August 23, 2016     Sample     Location                                                                 Chromium(VI)*   (micrograms/per gram of sample)   LR7502     Floor exiting the sanding booth through regulated area                          39.7642                              LR7503     Floor at the entrance door threshold leading into the Change room          18.0876 LR7504     Floor at center of Change room                                                           19.0502  LR7505     Threshold at door exiting the Change room from regulated area              13.0512 LR7506     Door handle exiting the Change room from regulated area                        0.4649     *micrograms of Chromium (VI) per gram of sample.