OSHA Inspection: JOSE GUEVARA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE GUEVARA in 1901 WEST MAIN ST, TROY, OH 45373 (NAICS 238140). OSHA activity number 341552693.

Watch Jose Guevara — free Get an email when a new federal OSHA severe-injury report for Jose Guevara is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE GUEVARA
Site address
1901 WEST MAIN ST
City
TROY
State
OH
ZIP
45373
Mailing
5345 LAMME RD, MORAINE, OH 45439
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.451 C01

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means:   Located along the side and rear perimeter exterior area of the commercial structure employees were observed working from two self-supported tubular welded frame tower systems with a 5 foot wide minimum base erected to a height in excess of 26 feet without the scaffold tower systems being secured to the structure or equivalent.
Recent events (1)
  • — Z (S) $2800

1926.451 E06 I

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(e)(6)(i): Integral prefabricated scaffold access frames shall be specifically designed and constructed for use as ladder rungs;   Located along the front, side and rear perimeter exterior area of the commercial structure employees were observed gaining access to three self-supported tubular welded frame tower systems by climbing the walkthrough scaffold end frames which were not specifically designed and constructed for such use in that rung lengths were less than 7 inches wide, rungs were not uniformly spaced and the rung spacing exceeded 16 ¾ inches in that the rung spacing was 13, 21, 18 and 22 inches between each rung, exposing employees climbing the end frame legs to fall potentials in excess of 13 feet.
Recent events (1)
  • — Z (S) $2800

1926.451 F07

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration.    Self-supported tubular welded frame scaffolding systems were not erected and used under the supervision of a competent person, in that a competent person qualified in scaffold erection did not supervise installation of protection from tipping, standard guardrails and compliant ladder access or equivalent to ensue such systems were erected or properly utilized.
Recent events (1)
  • — Z (S) $2800

1926.451 G01

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.   Located along the front, side and rear perimeter exterior area of the commercial structure employees were observed working from three self-supported tubular welded frame tower systems that were not protected by standard guardrails or personal fall arrest systems exposing employees to fall potentials in excess of 11 feet on two of the scaffold systems and in excess of 13 feet on the other scaffold system..
Recent events (1)
  • — Z (S) $2800