ROSWELL, GA —
OSHA Inspection: GS YUASA LITHIUM POWER, INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of GS YUASA LITHIUM POWER, INC in 1150 NORTHMEADOW PARKWAY SUITE 118, ROSWELL, GA 30076 (NAICS 335911). OSHA activity number 341569945.
Where did this inspection happen?
- Establishment
- GS YUASA LITHIUM POWER, INC
- Site address
- 1150 NORTHMEADOW PARKWAY SUITE 118
- City
- ROSWELL
- State
- GA
- ZIP
- 30076
- Mailing
- 1150 NORTHMEADOW PARKWAY SUITE 118, ROSWELL, GA 30076
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335911
- Employees
- 25
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $1817.00 · Current $1090.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Receiving Department: The employer failed to provide an "Exit" sign for each exit door. Employees were exposed to fire and entrapment hazards.
Recent events (2)
- — I (S) $1090.2
- — Z (S) $1817
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $2423.00 · Current $1454.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Laboratory area: The employer failed to provide the point of operation guarding for a Jet Turret Milling machine (model number JTN-2) when employees used it to process metal parts. Employees were exposed to caught-in hazards.
Recent events (2)
- — I (S) $1453.8
- — Z (S) $2423
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Throughout Facility: The employer failed to provide medical evaluations for employees required to wear 3M full-face and half-face respirators when working with the batteries. Employees were exposed to respiratory tract irritations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Throughout facility: The employer failed to identify the locations of fire extinguishers inside the buildings when working with batteries. Employees were exposed to fire hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GS YUASA LITHIUM POWER, INC
ROSWELL, GA—2019-02-20 00:00:00
GS YUASA LITHIUM POWER, INC
View GS YUASA LITHIUM POWER, INC's full OSHA safety record →
More inspections in this industry (NAICS 335911)
LANSING, MI—2026-07-09
LG ENERGY SOLUTION MICHIGAN INC
LAS VEGAS, NV—2026-07-08
RECHARGEABLE POWER ENERGY NORTH AMERICA LLC
FLORENCE, KY—2026-07-07
69288 - CLARIOS LLC
ALBUQUERQUE, NM—2026-06-29
RECON BATTERY WAREHOUSE
HOUSTON, TX—2026-06-29
ACE ENGINEERING
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341569945.