POCATELLO, ID —
OSHA Inspection: JON GREGORY
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of JON GREGORY in 1350 BALDY AVENUE, POCATELLO, ID 83201 (NAICS 238130). OSHA activity number 341570562.
Where did this inspection happen?
- Establishment
- JON GREGORY
- Site address
- 1350 BALDY AVENUE
- City
- POCATELLO
- State
- ID
- ZIP
- 83201
- Mailing
- PO BOX 1296, BLACKFOOT, ID 83221
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.28 A
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: (a) On or about June 21, 2016, An employee using a nail gun to frame walls was not using protective eyewear. NOTE: Abatement certification IS required for this item.
Recent events (3)
- — A (S) $1600
- — I (S) $800
- — Z (S) $1600
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) On or about June 21, 2016, and at times prior thereto, fall protection was not provided and used for workers including those engaged in wood framing activities 15.5 feet to over 25 feet above the ground or next lower level. NOTE: Abatement certification AND supporting documentation are required for this item.
Recent events (3)
- — A (S) $2800
- — I (S) $1400
- — Z (S) $2800
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Workers engaged in framing a 2-story building had not been provided training to recognize and protect themselves from fall hazards. NOTE: Abatement certification AND supporting documentation are required for this item.
Recent events (3)
- — A (S) $0
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) On or about June 21, 2016, and at times prior thereto, employees were using a Keller, Type III Household Duty aluminum extension ladder to access a flat roof. The top rung was only slightly above the upper landing surface. NOTE: Abatement certification is NOT required for this item. Corrected during inspection.
Recent events (3)
- — A (S) $1600
- — I (S) $800
- — Z (S) $1600
1926.1053 B08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder. (a) On or about June 21, 2016, and at times prior there to, employees were using unsecured extension ladder(s) to access upper levels. NOTE: Abatement certification IS required for this item.
Recent events (3)
- — A (S) $0
- — I (S) $0
- — Z (S) $0
1926.1053 B03
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.1053(b)(3): Ladder(s) were loaded beyond the maximum intended load for which they were built or beyond the manufacturer's rated capacity: (a) On or about June 21, 2016, and at times prior thereto, employees were using a Keller Type III Household 200 lb. Duty Rating aluminum extension ladder. At least one of the workers using exceeded the capacity by more than 100 lbs. NOTE: Abatement certification IS required for this item.
Recent events (3)
- — A (S) $1600
- — I (S) $800
- — Z (S) $1600
1926.1053 B15
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: (a) On June 21, 2016, and at times prior thereto, employees were using ladder(s) which had not been inspected. A Keller Type III Household duty aluminum extension ladder was used with multiple bends, dents, and damage. NOTE: 29 CFR 1926.32(f) defines a "Competent Person" as one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them. NOTE: Abatement certification IS required for this item.
Recent events (3)
- — A (S) $0
- — I (S) $0
- — Z (S) $0
1926.1053 B16
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. (a) On June 21, 2016, and at times prior thereto, employees were using a dented and bent aluminum extension ladder to access upper levels. NOTE: Abatement certification IS required for this item.
Recent events (3)
- — A (S) $0
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in ID
GOODING, ID—2026-07-10
DAHLGREN INDUSTRIAL INC.
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
MERIDIAN, ID—2026-07-10
DIAMOND CONCRETE, LLC
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
BOISE, ID—2026-07-09
MARK GUHO CONSTRUCTION COMPANY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341570562.