OSHA Inspection: MARS ELECTRICAL CONTRACTORS LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MARS ELECTRICAL CONTRACTORS LLC in 15 MILESTONE ROAD, DANBURY, CT 06811 (NAICS 238210). OSHA activity number 341579209.

Watch Mars Electrical Contractors LLC — free Get an email when a new federal OSHA severe-injury report for Mars Electrical Contractors LLC is published. One employer, no account, unsubscribe in one click.
Site address
15 MILESTONE ROAD
City
DANBURY
State
CT
ZIP
06811
Mailing
21 DIAMOND AVENUE, BETHEL, CT 06801
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
9
Ownership type
A

5 citations on file for this inspection.

1926.34 C

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $3367.00 · Current $1683.00 Reduced
29 CFR 1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency.    JOBSITE:  The white pipes and the flexible cords used to power hand tools were obstructing the main aisle ways and creating tripping hazards.
Recent events (2)
  • — I (S) $1683
  • — Z (S) $3367

1926.405 A02 II I

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:  JOBSITE:  The flexible cords used to power hand tools were lying on the main aisle ways and exposed to physical damages.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5612.00 · Current $2806.00 Reduced
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:    JOBSITE:  The unused opening on the fourplex electrical outlet box was not closed.
Recent events (2)
  • — I (S) $2806
  • — Z (S) $5612

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5612.00 · Current $2806.00 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    JOBSITE:  The employee installing electrical wiring while standing at the edge of the unguarded open-sided floor was not protected from the hazard of falling 18 feet to the ground by the use of guardrail systems, personal fall arrest systems or other equivalent means.
Recent events (2)
  • — I (S) $2806
  • — Z (S) $5612

1926.503 C03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(c)(3): Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill.  JOBSITE:  The employee exposed to the hazard of falling 18 feet to the ground while installing electrical wiring was not retained the information for fall protection training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0