Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: LOGAN COATINGS

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of LOGAN COATINGS in 2255 EAST FRONT STREET, LOGAN, OH 43138 (NAICS 332812). OSHA activity number 341588671.

Watch Logan Coatings — free Get an email when a new federal OSHA severe-injury report for Logan Coatings is published. One employer, no account, unsubscribe in one click.
Establishment
LOGAN COATINGS
Site address
2255 EAST FRONT STREET
City
LOGAN
State
OH
ZIP
43138
Mailing
PO BOX 459, WAYNESFIELD, OH 45896
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.107 I08

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3500.00 · Current $1400.00 Reduced
29 CFR 1910.107(i): Electrostatic hand spraying equipment -     29 CFR 1910.107(i)(8): Interlocks. The electrical equipment shall be so interlocked with the ventilation of the spraying area that the equipment cannot be operated unless the ventilation fans are in operation.    On or about June 30 2016; the employer did not have electrostatic hand spraying powder coating operation equipment interlocked with the spray booth ventilation fans.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $3500

1910.107 L04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(l)(4): Powder Coating - Operation and maintenance.  29 CFR 1910.107(l)(4)(i): All areas shall be kept free of the accumulation of powder coating dusts, particularly such horizontal surfaces as ledges, beams, pipes, hoods, booths, and floors.  On or about June 30, 2016, the employer failed to maintain the powder coating spray booth free of the accumulation of powder coating dust.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 L04 III

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(l)(4): Powder Coating - Operation and maintenance.  29 CFR 1910.107(l)(4)(iii): "No Smoking" signs in large letters on contrasting color background shall be conspicuously posted at all powder coating areas and powder storage rooms.  On or about June 30, 2016, the employer failed to post the required "No Smoking" warning sign at the powder coating area.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View LOGAN COATINGS's full OSHA safety record →