Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GUERRA UNDERGROUND LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GUERRA UNDERGROUND LLC in KITTY HAWK AND STAPLES BLVD, CORPUS CHRISTI, TX 78419 (NAICS 237110). OSHA activity number 341589828.

Watch Guerra Underground LLC — free Get an email when a new federal OSHA severe-injury report for Guerra Underground LLC is published. One employer, no account, unsubscribe in one click.
Site address
KITTY HAWK AND STAPLES BLVD
City
CORPUS CHRISTI
State
TX
ZIP
78419
Mailing
5114 BALCONES WOODS DR STE 300, AUSTIN, TX 78759
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $8730.00 · Current $8730.00
29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  In an excavation located parallel to a public roadway, employees installed a water main inside an irregular excavation that measured 11 feet deep at its deepest point, 35 feet long, and 25 feet wide. The exposed employee was not protected from a cave-in by the use of adequate shoring, trench-box, or adequate sloping of the excavation sides and ends.
Recent events (1)
  • — Z (S) $8730

1926.652 E01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(e)(1)(i): Members of support systems shall be securely connected together to prevent sliding, falling, kick-outs, or other predictable failure.  In an excavation located parallel to a public roadway, employees installed a water main inside an irregular excavation that measured 11 feet deep at its deepest point, 35 feet long, and 25 feet wide. The shield was missing spreader bar retainer pins in several locations.  The exposed employee was not protected from a cave-in by the use of adequate shoring/ trench-box.
Recent events (1)
  • — Z (S) $0

1926.652 E02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(e)(2)(i): Excavation of material to a level no greater than 2 feet (.61m) below the bottom of the members of a support system was permitted where the system was not designed to resist the forces calculated for the full depth of the trench.  In an excavation located parallel to a public roadway, employees installed a water main inside an irregular excavation that measured 11 feet deep at its deepest point, 35 feet long, and 25 feet wide. The shield placed inside the trench box was improperly positioned exceeding 2 feet from the bottom of the trench box and to the excavation ground floor.  The exposed employee was not protected from a cave-in by the use of adequate shoring/trench-box.
Recent events (1)
  • — Z (S) $0

View GUERRA UNDERGROUND LLC's full OSHA safety record →