Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DOMENICK'S ELECTRIC SEWER CLEANING COMPANY, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DOMENICK'S ELECTRIC SEWER CLEANING COMPANY, INC in 5779 COLONIAL BLVD, WILLOUGHBY, OH 44094 (NAICS 238220). OSHA activity number 341601417.

Watch Domenick'S Electric Sewer Cleaning Company, INC — free Get an email when a new federal OSHA severe-injury report for Domenick'S Electric Sewer Cleaning Company, INC is published. One employer, no account, unsubscribe in one click.
Site address
5779 COLONIAL BLVD
City
WILLOUGHBY
State
OH
ZIP
44094
Mailing
35886 LAKELAND BLVD, EASTLAKE, OH 44095
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
7
Ownership type
A

5 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $1871.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    On or before July 6, 2016, during the replacement of a residential sanitary sewer at 5779 Colonial Blvd, Willoughby, Ohio, the employer did not ensure each employee was instructed in the recognition and avoidance of unsafe conditions and the applicable regulations to their work environment to control or eliminate hazards associated with working in and around trenches and excavations.
Recent events (2)
  • — I (S) $1870.5
  • — Z (S) $3741

1926.100 A

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3207.00 · Current $1604.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    On or about July 6, 2016, during the replacement of a residential sanitary sewer line at 5779 Colonial Blvd, Willoughby, Ohio, the employer did not ensure employees working inside a trench were protected from head injuries posed from impact or falling objects by protective helmets (hard hats).
Recent events (2)
  • — I (S) $1603.5
  • — Z (S) $3207

1926.651 I03

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3741.00 · Current $1871.00 Reduced
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures:    On or about July 6, 2016, during the replacement of a residential sanitary sewer line at 5779 Colonial Blvd, Willoughby, Ohio, the employer did not ensure employees working inside a trench below an undermined concrete driveway were protected from the driveway collapsing or the driveway was supported to prevent collapse.
Recent events (2)
  • — I (S) $1870.5
  • — Z (S) $3741

1926.651 J02

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $3207.00 · Current $1604.00 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.     On or about July 6, 2016, during the replacement of a residential sanitary sewer line at 5779 Colonial Blvd, Willoughby, Ohio, the employer did not ensure employees working inside a trench were protected from excavated material that posed a hazard of falling or rolling into an excavation, by placing and keeping the material at least 2 feet from the edge of a trench or by the use of a retaining device.
Recent events (2)
  • — I (S) $1603.5
  • — Z (S) $3207

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3741.00 · Current $1871.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).      On or about July 6, 2016, during the replacement of a residential sanitary sewer line at 5779 Colonial Blvd, Willoughby, Ohio, the employer did not ensure employees working inside a trench, with varying depth of approximately 8 feet to approximately 9.5 feet deep and near 90 degree vertical walls, were protected from cave-ins by an adequately designed protection system.  The soil was classified as; Cohesive Sandy Clay, type B.
Recent events (2)
  • — I (S) $1870.5
  • — Z (S) $3741