OSHA Inspection: BEST ROOFING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BEST ROOFING LLC in 1601 MAIN STREET, STEVENS POINT, WI 54481 (NAICS 238160). OSHA activity number 341624401.

Watch Best Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Best Roofing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
BEST ROOFING LLC
Site address
1601 MAIN STREET
City
STEVENS POINT
State
WI
ZIP
54481
Mailing
2000 WEAVER CIRCLE, STEVENS POINT, WI 54482
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Deleted Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a)  On or about July 14, 2016 at 1601 Main Street in Stevens Point, employees were working on a porch roof surface at 10.5 ft. above surface level without utilizing fall protection equipment.  b)  On or about July 14 2016 at 1601 Main Street in Stevens Point, employees were working on the main roof surface at 18 ft. above surface level without utilizing fall protection equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1926.1053 B01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a)  On or about July 14, 2016 at 1601 Main Street in Stevens Point, employees were utilizing an extension ladder to access/egress a roof surface at 10.5 ft. above surface level without the side rails extended at least three feet above the upper landing surface.