ESTERO, FL —
OSHA Inspection: JAMES TOFFOLI CONSTRUCTION COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JAMES TOFFOLI CONSTRUCTION COMPANY in 23161 VIA COCONUT POINT, ESTERO, FL 33928 (NAICS 238120). OSHA activity number 341627545.
Where did this inspection happen?
- Establishment
- JAMES TOFFOLI CONSTRUCTION COMPANY
- Site address
- 23161 VIA COCONUT POINT
- City
- ESTERO
- State
- FL
- ZIP
- 33928
- Mailing
- PO BOX 7145, FORT MYERS, FL 33906
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.501 B12
- Issued
- Abate by
- Penalty
- Initial $4988.00 · Current $4988.00
General-duty citation text
29 CFR 1926.501(b)(12): Each employee engaged in the erection of precast concrete members (including, but not limited to the erection of wall panels, columns, beams, and floor and roof "tees") and related operations such as grouting of precast concrete members, who was 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems, and no other provision in paragraph (b) of this section provided for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. a) For employees working at 23161 Via Coconut Point in Estero, as observed on or about July 18, 2016. Employees were installing precast concrete floor panels at a height greater than 6 feet above the lower level without the use of a fall protection system in place. The employer provided a fall protection plan that was deficient in the following: -The fall protection plan did not document the reasons why the use of conventional fall protection systems are infeasible or why their use would create a greater hazard. -The fall protection plan did not include a written discussion of other measures that will be taken to reduce or eliminate the fall hazard for workers who cannot be protected with protection from the conventional fall protection systems. -The fall protection plan did not identify each location where methods of conventional fall protection cannot be used and controlled access zones were not clearly identified. -The fall protection plan identified the use of a safety monitoring system which cannot be used in precast placement operations. -The fall protection plan did not identify the names or other means of identification for each employee who is designated to work in the controlled access zones.
Recent events (2)
- — I (O) $4988
- — Z (S) $4988
1926.502 K05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(k)(5): The fall protection plan did not document the reasons why the use of conventional fall protection systems (guardrail systems, personal fall arrest systems, or safety nets systems) are infeasible or why their use would create a greater hazard. a) For employees working at 23161 Via Coconut Point in Estero, as observed on or about July 18, 2016. Employees were installing precast concrete floor panels at a height greater than 6 feet above the lower level.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.502 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(k)(6): The fall protection plan did not include a written discussion of other measures that would be taken to reduce or eliminate the fall hazard as required. a) For employees working at 23161 Via Coconut Point in Estero, as observed on or about July 18, 2016. Employees were installing precast concrete floor panels at a height greater than 6 feet above the lower level.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.502 K07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(k)(7): The fall protection plan did not identify each location where conventional fall protection methods cannot be used, these locations were not then classified as controlled access zones having to comply with the criteria of paragraph (g) of this section. a) For employees working at 23161 Via Coconut Point in Estero, as observed on or about July 18, 2016. Employees were installing precast concrete floor panels at a height greater than 6 feet above the lower level. The fall protection plan in use on the site identified the controlled access zones but did not comply with the criteria of 29 CFR 1926.502(g) in that a control line was not utilized.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.502 K08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(k)(8): Where no other alternative measure had been implemented, the employer did not implemented a safety monitoring in conformance with 1926.502(h). a) For employees working at 23161 Via Coconut Point in Estero, as observed on or about July 18, 2016. Employees were installing precast concrete floor panels at a height greater than 6 feet above the lower level. The fall protection plan in use on the site stated a safety monitoring system was in use during precast concrete placement. However, a safety monitoring system was not implemented.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.502 K09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(k)(9): The fall protection plan did not include a statement which provides the name or other method of identification for each employee who is designated to work in controlled access zones. a) For employees working at 23161 Via Coconut Point in Esterro, as observed on or about July 18, 2016. Employees were installing precast concrete floor panels at a height greater than 6 feet above the lower level.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections in this industry (NAICS 238120)
EL PASO, TX—2026-07-15
SURE STEEL
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
MIDLOTHIAN, VA—2026-07-09
B & J STEEL CONSTRUCTION, INC.
LYNCHBURG, VA—2026-07-09
GRAY'S WELDING LLC
More inspections in FL
MARIANNA, FL—2026-07-16
BRANNON BROTHERS CONSTRUCTION, LLC
LAKELAND, FL—2026-07-16
SOUTHERN MILLING & LUMBER, INC.
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
LAKELAND, FL—2026-07-16
ELIJAH WHOLESALE, LLC.
TAMPA, FL—2026-07-16
VALENCIA WHOLESALE, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341627545.