2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: TOMMY'S PLUMBING SERVICE, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TOMMY'S PLUMBING SERVICE, LLC in 132 FERNON ST, PHILADELPHIA, PA 19148 (NAICS 238220). OSHA activity number 341643435.

Watch Tommy'S Plumbing Service, LLC — free Get an email when a new federal OSHA severe-injury report for Tommy'S Plumbing Service, LLC is published. One employer, no account, unsubscribe in one click.
Site address
132 FERNON ST
City
PHILADELPHIA
State
PA
ZIP
19148
Mailing
3516 SOUTH 20TH STREET, PHILADELPHIA, PA 19145
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.405 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3563.00 · Current $2494.00 Reduced
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:    a) 132 Fernon St, Philadelphia, PA - Employees were operating an energized sawzall with a flexible power cord not used in continuous length without a splice thus exposing the employees to shock/electrocution hazards. This condition was observed on or about July 7, 2016.
Recent events (2)
  • — I (S) $2494.1
  • — Z (S) $3563

1926.405 G02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief was provided to prevent pull from being directly transmitted to joints or terminal screws:  a) 132 Fernon St, Philadelphia, PA - Employees were operating an energized sawzall that was missing strain relief on the power cord  to prevent pull from being directly transmitted to joints or terminal screws thus exposing the employees to shock hazards. This condition was observed on or about July 7, 2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4988.00 · Current $3492.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet or more in depth so as to require no more than 25 feet of lateral travel for employees:    a) 132 Fernon St, Philadelphia, PA - Employee were working in trench approximately 9 foot 3 inches long, 2 foot 7 inches wide and 5 foot 6 inches deep with no means of egress thus exposing the employee to cave-in hazards. This condition was observed on or about July 7, 2016.
Recent events (2)
  • — I (S) $3491.6
  • — Z (S) $4988

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4988.00 · Current $3492.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation or trench was not protected from cave-ins by an adequate protective system:    a) 132 Fernon St, Philadelphia, PA - Employee were working in trench approximately 9 foot 3 inches long, 2 foot 7 inches wide and 5 foot 6 inches deep with no protective system in place thus exposing the employee to cave-in hazards. This condition was observed on or about July 7, 2016.
Recent events (2)
  • — I (S) $3491.6
  • — Z (S) $4988

1926.651 K02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(k)(2): Where there was evidence of a situation that could result in a possible cave-in or other hazardous condition the competent person did not remove exposed employees until necessary precautions could be taken to ensure their safety:  a) 132 Fernon St, Philadelphia, PA - The employees were working in an trench approximately 9 foot 3 inch long by 2 foot 7 inch wide and 5 foot 6 inches deep in which the competent person did not make a determination of possible cave-in hazards and safe egress for the employee working in the trench. This violation exposed the employees to cave-in/struck-by hazards. This violation was observed on or about July 7, 2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341643435.