OSHA Inspection: DOMENICK ELECTRIC SEWER CLEANING CO. INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DOMENICK ELECTRIC SEWER CLEANING CO. INC. in 347 E WASHINGTON STREET, CHAGRIN FALLS, OH 44022 (NAICS 237110). OSHA activity number 341644318.

Watch Domenick Electric Sewer Cleaning CO. INC. — free Get an email when a new federal OSHA severe-injury report for Domenick Electric Sewer Cleaning CO. INC. is published. One employer, no account, unsubscribe in one click.
Site address
347 E WASHINGTON STREET
City
CHAGRIN FALLS
State
OH
ZIP
44022
Mailing
35886 LAKELAND BLVD., EASTLAKE, OH 44095
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
7
Ownership type
A

2 citations on file for this inspection.

1926.651 J02

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2138.00 · Current $1069.00 Reduced
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:    On or about July 14, 2016, during the replacement of a residential sanitary sewer line at 347 East Washington Street, Chagrin Falls, Ohio, the employer did not ensure employees working inside a trench were protected from the excavated material that posed a hazard of falling or rolling into an excavation, by placing and keeping the material at least 2 feet from the edge of a trench or by the use of a retaining device.
Recent events (2)
  • — I (S) $1069
  • — Z (S) $2138

1926.652 A01

Willful Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $24942.00 · Current $12471.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:    On or about July 14, 2016, during the replacement of a residential sanitary sewer line at 347 East Washington Street, Chagrin Falls, Ohio, the employer did not ensure employees working inside a trench, with varying depths of approximately 6 feet to approximately 8 feet deep and near 90 degree vertical walls, were protected from cave-ins by an adequately designed protection system.  The soil was classified as Cohesive Sandy Clay, type B.