Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TRAMM ELEVATOR COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TRAMM ELEVATOR COMPANY, INC. in 200 SPRINGS ROAD BLDG 4 & BLDG 78, BEDFORD, MA 01730 (NAICS 238290). OSHA activity number 341681955.

Watch Tramm Elevator Company, INC. — free Get an email when a new federal OSHA severe-injury report for Tramm Elevator Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
200 SPRINGS ROAD BLDG 4 & BLDG 78
City
BEDFORD
State
MA
ZIP
01730
Mailing
630 PARK STREET 3RD FLOOR, STOUGHTON, MA 02072
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238290
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2672.00 · Current $2672.00
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to the items of this section:  (a) Location - 200 Springs Road, Bedford, MA:  On or about 8/9/2016, the energy control procedure did not provide clear and specific instruction outlining the scope, rules, and techniques to be utilized to control hazardous energy during the servicing and maintenance of elevators.
Recent events (1)
  • — Z (S) $2672

1910.147 C06 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) Location - 200 Springs Road, Bedford, MA:  On or about 8/9/2016, an inspection sufficient to determine whether the energy control procedure was adequate to provide necessary protection during the servicing and maintenance of elevators has not been performed within the last year.
Recent events (1)
  • — Z (S) $0

1910.147 C07 I A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:  (a) Location - 200 Springs Road, Bedford, MA:  On or about 8/9/2016, elevator mechanics performing the work of authorized employees have not received training from the employer in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.