YOUNGSTOWN, OH —
OSHA Inspection: HYNES INDUSTRIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HYNES INDUSTRIES, INC. in 3805 HENDRICKS ROAD, YOUNGSTOWN, OH 44555 (NAICS 332114). OSHA activity number 341682847.
Where did this inspection happen?
- Establishment
- HYNES INDUSTRIES, INC.
- Site address
- 3805 HENDRICKS ROAD
- City
- YOUNGSTOWN
- State
- OH
- ZIP
- 44555
- Mailing
- 3805 HENDRICKS ROAD, YOUNGSTOWN, OH 44555
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332114
- Employees
- 180
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $8017.00 · Current $5612.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about August 8, 2016, the employer did not ensure hazardous energy control procedures were utilized for the safe application, usage, and removal of energy controls when employees changed the slitter knives (set-up) on the Paxson Machine Co. 60 Slitter Line. Energy Sources include, but are not limited to, electrical, pneumatic, and hydraulic power.
Recent events (2)
- — I (S) $5611.9
- — Z (S) $8017
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about August 8, 2016, machine operator(s) and machine helper(s) were exposed to machine hazards associated with rotating parts during the changing of the slitter knives (set-up) of a Paxson Machine Co. 60 Slitter Line. The employer did not ensure machine operator(s) and machine helper(s) implemented energy control procedures by isolating the machine from the energy source(s) [(d)(3)], affixing lockout device(s) [(d)(4)(i)], and verifying de-energization and isolation had been accomplished prior to setting up the slitter knives [(d)(6)]. Energy Sources include, but are not limited to, electrical, pneumatic, and hydraulic power.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $11224.00 · Current $7857.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about August 8, 2016, the employer did not ensure one or more methods of machine guarding were provided to protect machine operator and helpers from the hazards created by the ingoing nip points, rotating parts and moving steel coil material of the Paxson Machine Co. 60 Slitter Line. The unguarded rotating parts, ingoing nip points, and point of operation include; un-coiler/pay-off reel, guide rolls, slitter knives, material moving through the machine, scrap winders, re-coiler reel, and over-arm.
Recent events (2)
- — I (S) $7856.8
- — Z (S) $11224
More inspections at HYNES INDUSTRIES, INC.
YOUNGSTOWN, OH—1998-04-01 00:00:00
HYNES INDUSTRIES, INC
Youngstown, OH—1978-01-20 00:00:00
HYNES INDUSTRIES INC
Youngstown, OH—1977-09-30 00:00:00
HYNES INDUSTRIES INC
Youngstown, OH—1976-11-04 00:00:00
HYNES INDUSTRIES INC
Youngstown, OH—1974-12-18 00:00:00
HYNES INDUSTRIES INC
View HYNES INDUSTRIES, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332114)
STATESVILLE, NC—2026-06-23
161415 - CONSTRUCTION METAL PRODUCTS, INC.
FORT WORTH, TX—2026-06-03
CALIFORNIA EXPANDED METAL PRODUCTS
PAW PAW, MI—2026-06-03
HARLOFF MANUFACTURING COMPANY LLC
LIBERTYVILLE, IL—2026-06-02
MBA BUILDING SUPPLIES, INC.
BURTON, MI—2026-04-22
CENTURY ROLL
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341682847.