COLUMBUS, OH —
OSHA Inspection: SETTLE MUTER ELECTRIC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SETTLE MUTER ELECTRIC in 555 NATIONWIDE BLVD., COLUMBUS, OH 43215 (NAICS 238210). OSHA activity number 341684355.
Where did this inspection happen?
- Establishment
- SETTLE MUTER ELECTRIC
- Site address
- 555 NATIONWIDE BLVD.
- City
- COLUMBUS
- State
- OH
- ZIP
- 43215
- Mailing
- 711 CLAYCRAFT ROAD, COLUMBUS, OH 43230
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 160
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.1203 A
- Issued
- Abate by
- Penalty
- Initial $4811.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1203(a): Before it begins work at a worksite, each employer must ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary. a. On the site where employees were removing equipment from a confined space electrical vault, the competent person did not identify the working space as a confined space and evaluate potential hazards relating to working in the confined space thereby exposing employees to a electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $4811
1926.1203 E02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1203(e)(2)(iii): (iii) Before an employee enters the space, the internal atmosphere must be tested, with a calibrated direct-reading instrument, for oxygen content, for flammable gases and vapors, and for potential toxic air contaminants, in that order. Any employee who enters the space, or that employee's authorized representative, must be provided an opportunity to observe the pre-entry testing required by this paragraph. a. On the site where employees entered a Confined Space to remove equipment from the electrical vault, the employer did not test the atmosphere for oxygen content, flammable gases and vapors and potential toxic air contaminants before allowing employees to enter the confined space thereby exposing employees to unknown hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1205 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1205(a): (a) Before entry is authorized, each entry employer must document the completion of measures required by �1926.1204(c) by preparing an entry permit. a. On the site where employees were working in a confined space to remove equipment from a electrical vault with high voltage equipment, the employer did not document the completion of measures required prior to entering a confined space thereby exposing employees to a electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1203 E02 II
- Issued
- Abate by
- Penalty
- Initial $6815.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1203(e)(2)(ii): (ii) When entrance covers are removed, the opening must be immediately guarded by a railing, temporary cover, or other temporary barrier that will prevent an accidental fall through the opening and that will protect each employee working in the space from foreign objects entering the space. a. On the site where employees were working in a confined space to remove equipment, the attendant was exposed to a 14 foot fall hazard while standing at the opening where employees entered the electrical vault.
Recent events (2)
- — I (S) $0
- — Z (S) $6815
1926.1204 D
- Issued
- Penalty
- Initial $6413.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1204(d): (d) Provide the following equipment (specified in paragraphs (d)(1) through (9) of this section) at no cost to each employee, maintain that equipment properly, and ensure that each employee uses that equipment properly: 29 CFR 1926.1204(d)(8): Rescue and emergency equipment needed to comply with paragraph (i) of this section, except to the extent that the equipment is provided by rescue services. a. On the site where employees were removing equipment from a confined space, the employer did not provide rescue and emergency equipment such as, but not limited to, retrieval system and safety harness thereby exposing employees to a electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $6413
1926.1204 F
- Issued
- Penalty
- Initial $6815.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1204(f): (f) Provide at least one attendant outside the permit space into which entry is authorized for the duration of entry operations: a. On the site where employees were working in a confined space to remove equipment, the employer did not have at least one attendant on top in the event of an emergency thereby exposing employees to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $6815
1926.1207 A
- Issued
- Abate by
- Penalty
- Initial $4811.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1207(a): The employer must provide training to each employee whose work is regulated by this standard, at no cost to the employee, and ensure that the employee possesses the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under this standard. This training must result in an understanding of the hazards in the permit space and the methods used to isolate, control or in other ways protect employees from these hazards, and for those employees not authorized to perform entry rescues, in the dangers of attempting such rescue. a. On the site where employees were working in a electrical vault confined space, the employer did not provide training in the requirements and procedures for working in confined space conditions thereby exposing employees to a electrical hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $4811
1926.1416 D03 I
- Issued
- Abate by
- Penalty
- Initial $6815.00 · Current $6815.00
General-duty citation text
29 CFR 1926.1416(d)(3)(i): Telescopic boom cranes manufactured after February 28, 1992, must be equipped with a device which automatically prevents damage from contact between the load block, overhaul ball, or similar component, and the boom tip (or fixed upper block or similar component). The device(s) must prevent such damage at all points where two-blocking could occur. Temporary alternative measures: Clearly mark the cable (so that it can easily be seen by the operator) at a point that will give the operator sufficient time to stop the hoist to prevent two-blocking, and use a spotter when extending the boom. a. On the site where a Telescopic boom crane was used to lift tool boxes out of the Confined Space, the employer did not equip the crane with a Anti Two Block device thereby exposing employees to a struck-by hazard.
Recent events (2)
- — I (O) $6815
- — Z (S) $6815
More inspections at SETTLE MUTER ELECTRIC
COLUMBUS, OH—2008-05-07 00:00:00
SETTLE MUTER ELECTRIC
ORIENT, OH—2008-01-09 00:00:00
SETTLE MUTER ELECTRIC
COLUMBUS, OH—2007-05-09 00:00:00
SETTLE MUTER ELECTRIC
WESTERVILLE, OH—2004-10-20 00:00:00
SETTLE MUTER ELECTRIC
COLUMBUS, OH—2001-03-07 00:00:00
SETTLE MUTER ELECTRIC
View SETTLE MUTER ELECTRIC's full OSHA safety record →
More inspections in this industry (NAICS 238210)
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
NIAGARA FALLS, NY—2026-07-10
GAINES ELECTRICAL CONTRACTING, INC.
OGDENSBURG, NY—2026-07-10
S & L ELECTRIC, INC.
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
LYNCHBURG, VA—2026-07-09
WHITE ELECTRICAL SERVICES LLC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341684355.