HERRIN, IL —
OSHA Inspection: SOUTHERN ILLINOIS HEALTHCARE ENTERPRISE, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SOUTHERN ILLINOIS HEALTHCARE ENTERPRISE, INC. in 201 SOUTH 14TH STREET, HERRIN, IL 62948 (NAICS 622110). OSHA activity number 341686962.
Where did this inspection happen?
- Establishment
- SOUTHERN ILLINOIS HEALTHCARE ENTERPRISE, INC.
- Site address
- 201 SOUTH 14TH STREET
- City
- HERRIN
- State
- IL
- ZIP
- 62948
- Mailing
- 201 SOUTH 14TH STREET, HERRIN, IL 62948
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 622110
- Employees
- 50
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $6236.00 · Current $6236.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) The employer did not ensure that the procedure was developed and utilized for the control of potentially hazardous energy, such as but not limited to hydraulic and electric, for the employees who were performing servicing operations on equipment such as, but not limited to trash compactors. Servicing operations included, but not limited to, removing debris from the top of the compaction plate.
Recent events (1)
- — Z (S) $6236
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $8730.00 · Current $8730.00
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) On or about August 4, 2016, employees were exposed to machine hazards associated with moving parts, and caught-in hazards during servicing and cleaning of the trash compactors located in the laundry room. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (1)
- — Z (S) $8730
More inspections in this industry (NAICS 622110)
SAN JUAN, PR—2026-07-15
MUNICIPIO DE SAN JUAN
RIO PIEDRAS, PR—2026-07-15
CFSE
NORWALK, CA—2026-07-10
CPH HOSPITAL MANAGEMENT LLC
ANTIOCH, CA—2026-07-10
SUTTER DELTA MEDICAL CENTER
BURBANK, CA—2026-07-07
PROVIDENCE SAINT JOSEPH HOSPITAL
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341686962.