Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOUTHERN ILLINOIS HEALTHCARE ENTERPRISE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SOUTHERN ILLINOIS HEALTHCARE ENTERPRISE, INC. in 201 SOUTH 14TH STREET, HERRIN, IL 62948 (NAICS 622110). OSHA activity number 341686962.

Watch Southern Illinois Healthcare Enterprise, INC. — free Get an email when a new federal OSHA severe-injury report for Southern Illinois Healthcare Enterprise, INC. is published. One employer, no account, unsubscribe in one click.
Site address
201 SOUTH 14TH STREET
City
HERRIN
State
IL
ZIP
62948
Mailing
201 SOUTH 14TH STREET, HERRIN, IL 62948
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6236.00 · Current $6236.00
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) The employer did not ensure that the procedure was developed and utilized for the control of potentially hazardous energy, such as but not limited to hydraulic and electric, for the employees who were performing servicing operations on equipment such as, but not limited to trash compactors.  Servicing operations included, but not limited to, removing debris from the top of the compaction plate.
Recent events (1)
  • — Z (S) $6236

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8730.00 · Current $8730.00
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   a) On or about August 4, 2016, employees were exposed to machine hazards associated with moving parts, and caught-in hazards during servicing and cleaning of the trash compactors located in the laundry room.   The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements].  As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)],  and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (1)
  • — Z (S) $8730

CFSE

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341686962.