EULESS, TX —
OSHA Inspection: ROBERT SOWERS CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROBERT SOWERS CONSTRUCTION in 2521 STATE HWY 121, EULESS, TX 76039 (NAICS 236115). OSHA activity number 341705838.
Where did this inspection happen?
- Establishment
- ROBERT SOWERS CONSTRUCTION
- Site address
- 2521 STATE HWY 121
- City
- EULESS
- State
- TX
- ZIP
- 76039
- Mailing
- 25876 THE OLD ROAD #240, STEVENSON RANCH, CA 91381
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.102 A01
- Issued
- Penalty
- Initial $1499.00 · Current $1499.00
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. On the north side of the construction site, an employee engaged in installing metal straps from canopy used a pneumatic nail gun and was not wearing eye and face protection exposing him to struck-by hazards and eye injuries.
Recent events (1)
- — Z (S) $1499
1926.501 B01
- Issued
- Penalty
- Initial $2044.00 · Current $2044.00
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On the north and south side of the construction site, framing employees were engaged in installing roof bracing above the service yard and metal straps from an overhead canopy without fall protection and exposed to a fall hazard of approximately 17 feet to the ground.
Recent events (1)
- — Z (S) $2044
1926.1051 A
- Issued
- Penalty
- Initial $1999.00 · Current $1999.00
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided. On the north side of the construction site, the employer did not provide a ladder where the employee could access and egress the buildings overhead canopy. The employee was exposed to a potential fall hazard.
Recent events (1)
- — Z (S) $1999
More inspections at ROBERT SOWERS CONSTRUCTION
FRESNO, CA—2021-11-16 00:00:00
ROBERT SOWERS CONSTRUCTION
View ROBERT SOWERS CONSTRUCTION's full OSHA safety record →
More inspections in this industry (NAICS 236115)
REDDING, CA—2026-07-10
R&A RESOURCES, INC.
FRANCESTOWN, NH—2026-07-10
JM BUILDERS LLC
SAN JOSE, CA—2026-07-09
WALT OXLEY ENTERPRISES, INC.
BATAVIA, OH—2026-07-09
FISCHER SINGLE FAMILY HOMES IV, LLC
SARATOGA SPRINGS, UT—2026-07-09
JESSI CONSTRUCTION & PAINTING LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source