Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOHN HARTLESS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOHN HARTLESS, LLC in 415 WOODBRIDGE DRIVE, CHARLESTON, WV 25304 (NAICS 238160). OSHA activity number 341711455.

Watch John Hartless, LLC — free Get an email when a new federal OSHA severe-injury report for John Hartless, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JOHN HARTLESS, LLC
Site address
415 WOODBRIDGE DRIVE
City
CHARLESTON
State
WV
ZIP
25304
Mailing
117 BRYAN AVE., SAINT ALBANS, WV 25177
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2138.00 · Current $1500.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):      (a) 415 Woodbridge Dr. Charleston WV: On or about August 19, 2016, and times prior, employees were exposed to a fall of approximately 14 feet to the lowest portion of the ground, while conducting roofing work on a 5 in 12 slope roof. The employees were not protected by a personal fall arrest system.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2138

1926.502 D15

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not capable of supporting at least 5,000 pounds per employee attached.    (a) 415 Woodbridge Dr. Charleston WV: On or about August 19, 2016, and times prior, employees were exposed to a fall of approximately 11 feet 9 inches to the lowest portion of the ground, while conducting roofing work on a 5 in 12 slope roof. Two employees were tied off to the same anchor point which is not rated for more than 5,000 pounds.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 D16 III

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    (a) 415 Woodbridge Dr. Charleston WV: On or about August 19, 2016, and times prior, employees were exposed to a fall of approximately 11 feet 9 inches to the lowest portion of the ground, while conducting roofing work on a 5 in 12 slope roof. An employee had too much slack in the rope and would have hit the concrete parking pad while wearing fall protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:    (a) 415 Woodbridge Dr. Charleston WV: On or about August 19, 2016, and times prior, employees were exposed to a fall of approximately 14 feet to the lowest portion of the ground, while conducting roofing work on a 5 in 12 slope roof. The employer did not provide a training program to enable the employees to recognize fall hazards and how to minimize the hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2138.00 · Current $1500.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:      (a) 415 Woodbridge Dr. Charleston WV: On or about August 19, 2016, and times prior, employees used an extension ladder to access the 5 in 12 pitched roof to conduct roofing operations. The ladder did not extend at least 3 feet above the landing surface, exposing employees to a fall of approximately 14 feet to the lowest portion of the ground.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2138

UNKNOWN

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341711455.