DENVER, CO —
OSHA Inspection: METRO METAL SUPPLY, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of METRO METAL SUPPLY, INC. in 50.5 E 56TH AVE, DENVER, CO 80216 (NAICS 332322). OSHA activity number 341735629.
Where did this inspection happen?
- Establishment
- METRO METAL SUPPLY, INC.
- Site address
- 50.5 E 56TH AVE
- City
- DENVER
- State
- CO
- ZIP
- 80216
- Mailing
- 50.5 E 56TH AVE, DENVER, CO 80216
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $2272.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure and employee training to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated, and rendered inoperative in accordance with 29 CFR 1910.147(c)(4): (a) Metro Metal Supply, Inc. 50.5 East 56th, Avenue, Denver, CO: On and prior to August 29th, 2016, the employer did not establish a program consisting of an energy control procedure and employee training to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated, and rendered inoperative, including but not limited to the following: (1) RAS XL Center press brake machine (2) Schechtl cutter/sheer machine (S/N 8620) (3) Schechtl cutter/sheer machine (S/N MT10885) (4) Schechtl press brake machine Abatement Note: As part of an energy-control program, employers must: (1) Establish energy-control procedures for removing the energy supply from machines and for putting appropriate lockout or tagout devices on the energy-isolating devices to prevent unexpected reenergization. When appropriate, the procedure also must address stored or potentially reaccumulated energy. (2) Train employees on the energy-control program, including the safe application, use, and removal of energy controls; and (3) Inspect these procedures periodically (at least annually) to ensure that they are being followed and that they remain effective in preventing employee exposure to hazardous energy. The energy-control procedures must outline the scope, purpose, authorization, rules, and techniques that employees will use to control hazardous energy sources, as well as the means that will be used to enforce compliance. These procedures must provide employees at least the following information: (1) A statement on how to use the procedures; (2) Specific procedural steps to shut down, isolate, block, and secure machines; (3) Specific steps designating the safe placement, removal, and transfer of lockout/tagout devices and identifying who has responsibility for the lockout/tagout devices; and (4) Specific requirements for testing machines to determine and verify the effectiveness of lockout devices, tagout devices, and other energy-control measures. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- — I (S) $1500
- — Z (S) $2272
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $2271.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Metro Metal Supply, Inc. 50.5 East 56th, Avenue, Denver, CO: The employer did not ensure the point of operation on the Schechtl hydraulic press brake was guarded to prevent employees from having any part of the their body in the danger zone during operation. Employee(s) were not protected by safe distance and/or a physical barrier to prevent contact with the point of operation. This hazard exposed employees to an amputation hazard. (b) The employer did not ensure the point of operation on the RAS metal folding hydraulic press brake was guarded to prevent employees from having any part of their body in the danger zone during operation. Employee(s) were not protected by safe distance and/or a physical barrier to prevent contact with the point of operation. This hazard exposed employees to an amputation hazard. Abatement Note: Abatement certification is required for this item (see enclosed Abatement-Certification Worksheet"). Abatement Note: See 1997 OSHA compliance directive CPL 02-01-125 titled "Guidelines for Point of Operation Guarding of Power Press Brakes" for safeguarding by maintaining a "safe distance" if the employer demonstrates that maintaining a safe distance is limited to one-time only fabrication of made-to-order or custom-made piece parts. Small quantity runs, typically performed in a job shop establishment may be affected by this provision; high volume piece part rates of production will not. A "small quantity run" means fabrication of more than one of the same piece parts over a continuous timeframe of no more than four hours per month.
Recent events (2)
- — I (S) $1500
- — Z (S) $2271
1910.157 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(g)(2): An educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting was not provided to all employees upon initial employment, and at least annually thereafter: (a) Metro Metal Supply, Inc. 50.5 East 56th, Avenue, Denver, CO: On and prior to August 29th, 2016, the employer had not ensured appropriate training for all employees expected to use portable fire extinguishers. Abatement Note: Abatement certification is required for this item (see enclosed Abatement-Certification Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Metro Metal Supply, Inc. 50.5 East 56th, Avenue, Denver, CO: On and prior to August 29th, 2016, each circuit breaker located in the South wall electrical panel was not labeled with its purpose. Abatement Note: Abatement certification is required for this item (see enclosed Abatement-Certification Worksheet").
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332322)
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
BRIDGEPORT, WV—2026-07-14
MID ATLANTIC METALWORKS INC.
KISSIMMEE, FL—2026-07-14
JELD-WEN
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341735629.