Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: HY DESIGN & DEVELOPMENT LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HY DESIGN & DEVELOPMENT LLC in 61-36 215TH STREET, OAKLAND GARDENS, NY 11364 (NAICS 236115). OSHA activity number 341756989.

Watch HY Design & Development LLC — free Get an email when a new federal OSHA severe-injury report for HY Design & Development LLC is published. One employer, no account, unsubscribe in one click.
Site address
61-36 215TH STREET
City
OAKLAND GARDENS
State
NY
ZIP
11364
Mailing
47-27 195TH STREET, FLUSHING, NY 11358
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
7
Ownership type
A

8 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2672.00 · Current $2672.00
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364  Employees were using a 2 receptacle outlet that was not mounted in a box, inside a wall, as it is designed.  WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19   b) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364  Employees were using a 4 outlet surge protector that is designed for indoor use, as extension cord at an outdoor   construction site.  WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $2672

1926.451 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2672.00 · Current $2672.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)   a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364  employees were working on a tubular welded frame scaffold, approximately 20-feet above a lower level, that was not fully decked at the work level.  WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $2672

1926.451 C02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units:  a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364  Employees were working on a tubular welded frame scaffold, approximately 20-feet above a lower level, that was supported on an unstable wooden platform.  WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $0

1926.451 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:  a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364  Employees were working on a tubular welded frame scaffold that did not have base plates or mud sills installed.  WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:  a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364  Employees working on a tubular welded frame scaffold, approximately 20-feet above a lower level, climbed up and down the frame to access the work levels.  WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $0

1926.452 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:  a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364  Employees were working on a tubular welded frame scaffold, approximately 20-feet above a lower level, that was missing cross bracing at several positions on the scaffold.  WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2672.00 · Current $2672.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364  Employees were constructing a 2-story home and were working on the outside of the upper level, approximately 25-feet above the next lower level, without fall protection.  WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $2672

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) On or about September 8, 2016- job site of 61-36 215th Street, Oakland Gardens, NY 11364  Employees were constructing a 2-story home and were working on the outside of the upper level, approximately 25-feet above the next lower level, without fall protection training.  WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PERSUANT TO 29 CFR 1903.19
Recent events (1)
  • — Z (S) $0

View HY DESIGN & DEVELOPMENT LLC's full OSHA safety record →