BEAVER MEADOWS, PA —
OSHA Inspection: JAMES C. GALLAGHER
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JAMES C. GALLAGHER in 1129 BERWICK STREET, BEAVER MEADOWS, PA 18216 (NAICS 238160). OSHA activity number 341761252.
Where did this inspection happen?
- Establishment
- JAMES C. GALLAGHER
- Site address
- 1129 BERWICK STREET
- City
- BEAVER MEADOWS
- State
- PA
- ZIP
- 18216
- Mailing
- P.O. BOX 178 139 BROAD STREET, BEAVER MEADOWS, PA 18216
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2672.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). a) Main Roof Surface, Residence, 1129 Berwick Street, Beaver Meadows, PA - Employees on the steep sloped main roof of a residence engaged in replacement shingling activities were not protected from falling and were exposed to a fall hazard between eighteen-foot, eight-inches (18'8") and twenty eight-foot, eight-inches (28'8") above ground level, as observed on or about September 9, 2016. b) Addition Roof Surface, Residence, 1129 Berwick Street, Beaver Meadows, PA - Employees on the low sloped roof of a residence addition engaged in replacement shingling activities were not protected from falling and were exposed to a fall hazard between eleven-foot, six-inches (10'8") and eleven-foot, six-inches (11'6") above ground level, as observed on or about September 9, 2016. c) Front Porch Roof Surface, Residence, 1129 Berwick Street, Beaver Meadows, PA - Employees on the low sloped roof of a residence addition engaged in clearing roofing debris were not protected from falling and were exposed to a fall hazard of eleven-foot, six-inches (11'6") above ground level, as observed on or about September 9, 2016.
Recent events (2)
- — I (S) $1500
- — Z (S) $2672
1926.1053 B01
- Issued
- Penalty
- Initial $1604.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) Front Porch, Residence, 1129 Berwick Street, Beaver Meadows, PA - Employees used a Model D6024-2 Werner Fiberglass Type I Extension Ladder for roof access/egress with fly section side rails that extended a eighteen-inches (18") above the top of the front porch roof eave exposing the employees to a twenty seven-foot (27') fall hazard, as observed on or about September 9, 2016.
Recent events (2)
- — I (S) $1000
- — Z (S) $1604
1926.1053 B06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level. a) Back Room Roof Surface, Residence, 1129 Berwick Street, Beaver Meadows, PA - An unsecured Model FE3216 Louisville Fiberglass Extension Ladder placed on a sloped roof was used for main roof access/egress exposing employees to an eighteen-foot, eight-inch (18'8") fall hazard, as observed on or about September 9, 2016.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B10
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(10): The tops of a non-self-supporting ladder with more than one support attachment were not placed with the two rails supported equally. a) Addition, Residence, 1129 Berwick Street, Beaver Meadows, PA - The side rails of the fly section of a Model D1332-2 Werner Aluminum Type I Extension Ladder used for roof access/egress were placed against the rake edge of a sloped roof exposing employees to a ten-foot, eight-inch (10'8") fall hazard, as observed on or about September 9, 2016.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in PA
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
JEFFERSON HILLS, PA—2026-07-16
MARATHON PETROLEUM COMPANY ASPHALT TERMINAL
SMITHFIELD, PA—2026-07-16
CARLISLE CONSTRUCTION MATERIALS
PITTSBURGH, PA—2026-07-15
DREAM GREENER LAWN & LANDSCAPE
COCHRANTON, PA—2026-07-15
CRAWFORD COUNTY HARDWOODS, LLC
Source