Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KNOCK BUILDERS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KNOCK BUILDERS LLC in 8910 PINE HOLLOW PLACE, VERONA, WI 53593 (NAICS 238130). OSHA activity number 341800522.

Watch Knock Builders LLC — free Get an email when a new federal OSHA severe-injury report for Knock Builders LLC is published. One employer, no account, unsubscribe in one click.
Establishment
KNOCK BUILDERS LLC
Site address
8910 PINE HOLLOW PLACE
City
VERONA
State
WI
ZIP
53593
Mailing
744 FARNHAM STREET, COLUMBUS, WI 53925
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2138.00 · Current $750.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    On or about September 27, 2016, individuals working near and/or underneath suspended loads such as but not limited to: residential roof trusses, were doing so without head protection.
Recent events (2)
  • — I (S) $750
  • — Z (S) $2138

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3741.00 · Current $1500.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     On or about September 27, 2016, individuals installing residential roof trusses at a height greater than six feet were doing so without fall protection.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $3741

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2672.00 · Current $750.00 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    On or about September 27, 2016 to access the working level, individuals were utilizing a portable aluminum extension ladder that was not extended three feet above the landing surface.
Recent events (2)
  • — I (S) $750
  • — Z (S) $2672

1926.503 B01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  On or about September 27, 2016, the employer did not prepare / maintain a certification record pertaining to Fall Protection training.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.602 C01 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.602(c)(1)(ii): Modifications or additions affecting the safe operation of the equipment were made without the manufacturer's written approval: Note:  If such modifications or changes were made, the capacity, operation, and maintenance instruction plates, tags, or decals should have been changed accordingly.  On or about September 27, 2016, to assist with the lifting and placement of residential roof trusses, a chain sling was utilized / secured to one mast fork and to the roof trusses in such a manner thus affecting the safe operation of the equipment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341800522.