Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WILLCO SERVICES, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of WILLCO SERVICES, INC. in EOG WELL SITE, LEPORI 2H 15 MILES SOUTH OF GONZALES, TX, GONZALES, TX 78629 (NAICS 213112). OSHA activity number 341827467.

Watch Willco Services, INC. — free Get an email when a new federal OSHA severe-injury report for Willco Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
EOG WELL SITE, LEPORI 2H 15 MILES SOUTH OF GONZALES, TX
City
GONZALES
State
TX
ZIP
78629
Mailing
1304 SWIFT ST, REFUGIO, TX 78377
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
30
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $8873.00
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors.  Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:    On or about October 5, 2016, employees depressurizing the well head were exposed to the hazards associated with ignition of hydrocarbon vapors. An open top blow down tank was located with known ignition sources within 100 feet from the tank, and vapors were vented into the atmosphere, where they could come into contact with ignition sources. Ignition sources ranging from 7 feet to 80 feet in proximity to the tank included but were not limited to live electrical conductors, electrical tools, a gasoline generator and running vehicles.
Recent events (2)
  • — I (O) $8873
  • — Z (S) $8873

1910.138 A

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $8873.00
29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes.    On or about October 5, 2016, employees were using black nitrile coated gloves not designed to be used in extreme temperature conditions, exposing employees to the hazards of fire and explosions, resulting in burns to the hands.
Recent events (2)
  • — I (O) $8873
  • — Z (S) $8873

1910.151 B

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $8873.00
29 CFR 1910.151(b): Adequate first aid supplies were not readily available:    On or about October 5, 2016, and at times prior thereto, employees were exposed to delayed emergency medical treatment for over 20 minutes after sustaining burns from a flash fire. The remote site location off a rural ranch road in Gonzales County required three ambulances to treat, recover and transport five injured workers. The site lacked sterile supplies for immediate treatment of the burns.
Recent events (2)
  • — I (O) $8873
  • — Z (S) $8873

1910.307 C

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $8873.00
29 CFR 1910.307(c): Equipment, wiring and installations of equipment in hazardous (classified) locations was not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:    On or about October 5, 2016,  the employer did not ensure that electrical equipment used or present in a flammable gas environment was intrinsically safe, exposing employees to the hazard of fire and explosions.  Flammable gases were being released from a wellhead in the vicinity of electrical panels, electrical torque wrenches, and energized conductors for a solar panel, none of which were intrinsically safe for hazardous locations.
Recent events (2)
  • — I (O) $8873
  • — Z (S) $8873

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341827467.