OSHA Inspection: HYBRID CONSTRUCTION, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of HYBRID CONSTRUCTION, LLC in 2324 MEMPHIS STREET, PHILADELPHIA, PA 19125 (NAICS 236116). OSHA activity number 341855294.

Watch Hybrid Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Hybrid Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2324 MEMPHIS STREET
City
PHILADELPHIA
State
PA
ZIP
19125
Mailing
1732 N. HOWARD STREET, PHILADELPHIA, PA 19122
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.451 B01

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $2173.00 · Current $2173.00
29 CFR 1926.451(b)(1):  Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports:    a) 2324-28 Memphis St, Philadelphia, PA - The employees were working off of a fabricated frame scaffold approximately 28 feet long, 39 feet high and 5 feet wide which was not fully planked or decked on all working levels between the front uprights and the guardrail supports. This hazard exposed the employees to a fall hazard ranging from approximately 13 to 20 feet. This condition was observed on October 20, 2016.
Recent events (2)
  • — I (O) $2173
  • — Z (S) $2173

1926.451 C02

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames and uprights were not bear firm foundation:    a) 2324-28 Memphis St, Philadelphia, PA - The employees were working off of a fabricated frame scaffold approximately 28 feet long, 39 feet high and 5 feet wide which did not bear on a firm foundation. This hazard exposed the employees to a scaffold collapse hazard. This condition was observed on October 20, 2016.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.451 G01 VII

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $3803.00 · Current $3803.00
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level by use of personal fall arrest systems or guardrail systems:    a) 2324-28 Memphis St, Philadelphia, PA - The employees were working off of a fabricated frame scaffold approximately 28 feet long, 39 feet high and 5 feet wide which did not have a guardrail system installed on the working levels of the scaffold. This hazard exposed the employees to a fall hazard ranging from approximately 13 to 20 feet. This condition was observed on October 20, 2016.
Recent events (2)
  • — I (O) $3803
  • — Z (S) $3803

1926.451 E01

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): Where scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers or stairway-type ladders was not used for access:    a) 2324-28 Memphis St, Philadelphia, PA - The employees were working off of a fabricated frame scaffold approximately 28 feet long, 39 feet high and 5 feet wide which did not have proper access for the employees to reach the various working levels of the scaffold. This hazard exposed the employees to a fall hazard. This condition was observed on October 20, 2016.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.501 B01

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $3803.00 · Current $3803.00
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge 6 feet or more above a lower level was not protected from falling by the use of a guardrail system, safety net system, or personal fall arrest system:    a) 2324-28 Memphis St, Philadelphia, PA - The employer did not ensure that employees were protected from falling through floor holes on the walking/working surface, approximately 9 feet, to the lower level by not using some type of fall protection system thus exposing the employees to fall hazards on or about October 20, 2016.
Recent events (2)
  • — I (O) $3803
  • — Z (S) $3803

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341855294.