On , OSHA opened a complaint safety inspection of GRIFFETH FORD in 213 MAIN STREET, PRESQUE ISLE, ME 04769 (NAICS 441110). OSHA activity number 341857704.

Watch Griffeth Ford — free Get an email when a new federal OSHA severe-injury report for Griffeth Ford is published. One employer, no account, unsubscribe in one click.
Establishment
GRIFFETH FORD
Site address
213 MAIN STREET
City
PRESQUE ISLE
State
ME
ZIP
04769
Mailing
213 MAIN STREET, PRESQUE ISLE, ME 04769
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
11
Ownership type
A

5 citations on file for this inspection.

1910.132 D02

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:  Facility - The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment.
Recent events (1)
  • — Z (O) $0

1910.134 C02 I

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  Service Area - The employer did not provide employees who voluntarily use a filtering facepiece the information contained in Appendix D.
Recent events (1)
  • — Z (O) $0

1910.134 D01 II

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification:  Service Department - Employees are using a single strap Gerson filtering face piece which is not NIOSH-certified.
Recent events (1)
  • — Z (O) $0

1910.157 E02

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  Auto Technicians' Workbench - Two Badger fire extinguishers mounted on the technicians' workbench were not visually inspected at least monthly.
Recent events (1)
  • — Z (O) $0

1910.304 G05

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  Service Bay - The Midtronics GR1-190 Diagnostic Conductance Charger was missing a grounding pin.
Recent events (1)