1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ALLEGHENY STRUCTURAL COMPONENTS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ALLEGHENY STRUCTURAL COMPONENTS, INC. in 3778 ONEIDA VALLEY ROAD, EMLENTON, PA 16373 (NAICS 444190). OSHA activity number 341862274.

Watch Allegheny Structural Components, INC. — free Get an email when a new federal OSHA severe-injury report for Allegheny Structural Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3778 ONEIDA VALLEY ROAD
City
EMLENTON
State
PA
ZIP
16373
Mailing
3778 ONEIDA VALLEY ROAD, EMLENTON, PA 16373
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
444190
Employees
21
Ownership type
A

3 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $3563.00 · Current $2138.00 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8 hour time weighted average sound level (TWA) of 85 dBA:    a)  At the facility, on or about November 3, 2016 - A continuing and effective hearing conservation program was not instituted when employee noise exposure equaled or exceeded an 8 hour time-weighted average sound level (TWA) of 85 dBA.  An employee designated as a Diagonal Saw Operator had an exposure to continuous noise at a dose of 97.65%.  The exposure is approximately 1.953 times the OSHA action level of 85 dBA.  This is equivalent sound level of 89.83 dBA.    b)  At the facility, on or about November 3, 2016 - A continuing and effective hearing conservation program was not instituted when employee noise exposure equaled or exceeded an 8 hour time-weighted average sound level (TWA) of 85 dBA.  An employee designated as a Press Operator had an exposure to continuous noise at a dose of 70.52%.  The exposure is approximately 1.410 times the OSHA action level of 85 dBA.  This is equivalent sound level of 87.48 dBA.
Recent events (2)
  • — I (S) $2138
  • — Z (S) $3563

1910.95 G01

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 8111

29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:  a)  At the facility, on or about November 3, 2016 - An audiometric testing program was not established or maintained by making audiometric testing available to all employees whose exposures equaled or exceeded an 8-hour time-weighted average of 85 decibels.  An employee designated as a Diagonal Saw Operator had an exposure to continuous noise at a dose of 97.65%.  The exposure is approximately 1.953 times the OSHA action level of 85 dBA.  This is equivalent sound level of 89.83 dBA.  b)  An audiometric testing program was not established or maintained by making audiometric testing available to all employees whose exposures equaled or exceeded an 8-hour time-weighted average of 85 decibels.  An employee designated as a Press Operator had an exposure to continuous noise at a dose of 70.52%.  The exposure is approximately 1.410 times the OSHA action level of 85 dBA.  This is equivalent sound level of 87.48 dBA.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 K02

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 8111

29 CFR 1910.95(k)(2): The training program was not repeated annually for each employee included in the hearing conservation program:  a) At the facility, on or about November 3, 2016 - The training program was not repeated annually for each employee included in the hearing conservation program.  An employee designated as a Diagonal Saw Operator had an exposure to continuous noise at a dose of 97.65%.  The exposure is approximately 1.953 times the OSHA action level of 85 dBA.  This is equivalent sound level of 89.83 dBA.  b)  The training program was not repeated annually for each employee included in the hearing conservation program.  An employee designated as a Diagonal Saw Operator had an exposure to continuous noise at a dose of 97.65%.  The exposure is approximately 1.953 times the OSHA action level of 85 dBA.  This is equivalent sound level of 89.83 dBA.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View ALLEGHENY STRUCTURAL COMPONENTS, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341862274.