CALDWELL, ID —
OSHA Inspection: DENNIS DILLON DODGE CHRYSLER JEEP, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DENNIS DILLON DODGE CHRYSLER JEEP, LLC in 4025 CLEVELAND BLVD, CALDWELL, ID 83607 (NAICS 441229). OSHA activity number 341866028.
Where did this inspection happen?
- Establishment
- DENNIS DILLON DODGE CHRYSLER JEEP, LLC
- Site address
- 4025 CLEVELAND BLVD
- City
- CALDWELL
- State
- ID
- ZIP
- 83607
- Mailing
- 2777 S. ORCHARD, BOISE, ID 83702
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441229
- Employees
- 70
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $8908.00 · Current $0.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were working from powered industrial truck, elevated work platforms, without fall protection. a) On or about October 26, 2016 or prior thereto: Employees were on a wood pallet platform suspended approximately 10 feet high by a Hyster 40 Model H40XMS, S/N D001H03548U Powered Industrial Truck. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $8908
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). a) On or about October 26, 2016 or prior thereto: Operators of the Hyster 40 Model H40XMS, S/N D001H03548U Powered Industrial Truck were not trained in its operation, and the evaluation required per 29 CFR 1910.178(l). NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $8908.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. a) On or about October 26, 2016 or prior thereto: Employees on a pallet platform suspended approximately 10 feet high by a Hyster 40 Model H40XMS, S/N D001H03548U Powered Industrial Truck were not provided with fall protection. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $8908
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). a) On or about October 26, 2016 or prior thereto: Employees on a pallet platform suspended approximately 10 feet high by a Hyster 40 Model H40XMS, S/N D001H03548U Powered Industrial Truck were not provided with fall protection. The employer had not assessed the workplace to determine if fall hazards were present prior to this operation. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $5345.00 · Current $4500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) On or about October 26, 2016, or prior thereto: Oil line maintenance work was conducted on lines approximately 12.5 feet above ground level, in the path of a motorized garage door. The garage door was not disconnected prior to the commencement of the maintenance work. The employer does not have an energy control program to prevent unexpected energization of equipment. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $4500
- — Z (S) $5345
More inspections in this industry (NAICS 441229)
MOSES LAKE, WA—2026-06-30
WA317991865 - PREMIER TRAILER SOLUTIONS INC
SPOKANE, WA—2024-12-17
WA317983747 - NORTHWEST GOLF CARS, INC
CHEHALIS, WA—2023-09-11 00:00:00
WA317975973 - PRIDE TRUCK SALES LP
CHEHALIS, WA—2023-03-08 00:00:00
WA317972964 - PRIDE TRUCK SALES LP
CHEHALIS, WA—2022-11-28 00:00:00
WA317971521 - PRIDE TRUCK SALES LP
More inspections in ID
BOISE, ID—2026-07-16
RAYMOND MANAGEMENT COMPANY
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
MIRZON CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
EASTER SEALS - GOODWILL NORTHERN ROCKY MOUNTAINS
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341866028.