OSHA Inspection: TREPIS INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TREPIS INC. in 6222 N. SUMMIT ST., TOLEDO, OH 43612 (NAICS 236118). OSHA activity number 341880268.

Watch Trepis INC. — free Get an email when a new federal OSHA severe-injury report for Trepis INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TREPIS INC.
Site address
6222 N. SUMMIT ST.
City
TOLEDO
State
OH
ZIP
43612
Mailing
6222 N. SUMMIT ST., TOLEDO, OH 43612
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
15
Ownership type
A

4 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1087.00 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use.    a) Trepis Inc. DBA American Builders Restoration, located at 6222 N Summit St. Toledo, OH, 43612, on or about November 1, 2016, the employer did not develop a written respiratory protection program for employees utilizing full face tight fitting respirators during mold remediation.
Recent events (2)
  • — I (S) $1087
  • — Z (S) $2173

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace.   a)    Trepis Inc. DBA American Builders Restoration, located at 6222 N Summit St. Toledo, OH, 43612, on or about November 1, 2016, the employer did not ensure that employees utilizing full face tight fitting respirators were provide a medical evaluation to determine the employee's ability to use a respirator, before requiring the employees to utilize one during mold remediation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT).   a) Trepis Inc. DBA American Builders Restoration, located at 6222 N Summit St. Toledo, OH, 43612, on or about November 1, 2016, the employer did not ensure that employees utilizing tight fitting respirators during mold remediation passed a fit test for the respirators use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function.  a) Trepis Inc. DBA American Builders Restoration, located at 6222 N Summit St. Toledo, OH, 43612, on or about November 1, 2016, the employer did not ensure that employees using tight fitting respirators did not have facial hair that comes between the sealing surface of the face piece and the face or that could interfere with valve function.