JACKSON, MS —
OSHA Inspection: FOUR SEASONS MASONRY
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of FOUR SEASONS MASONRY in 7020 MEDGER EVERS BLVD, JACKSON, MS 39213 (NAICS 238140). OSHA activity number 341892982.
Where did this inspection happen?
- Establishment
- FOUR SEASONS MASONRY
- Site address
- 7020 MEDGER EVERS BLVD
- City
- JACKSON
- State
- MS
- ZIP
- 39213
- Mailing
- 2051 OAK GROVE ROAD, HATTIESBURG, MS 39401
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $3803.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: (a) Backside of the school left scaffold - On or about November 2, 2016 three employees were exposed to a fall hazard due to a scaffold 16 feet 4 inches above the ground not being fully decked or planked.
Recent events (1)
- — Z (S) $3803
1926.451 C01 II
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $3803.00
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other). (a) Backside of the school right scaffold - On or about November 2, 2016 employees were exposed to a fall hazard due to a scaffold 21 feet 1 inches above the ground not being tied to the building.
Recent events (1)
- — Z (S) $3803
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $3803.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. (a) Backside of the school left scaffold - On or about November 2, 2016 three employees were exposed to a fall hazard due to a scaffold 16 feet 4 inches above the ground not having a ladder installed. (b) Backside of the school right scaffold - On or about November 2, 2016 employees were exposed to a fall hazard while working on a scaffold 21 feet 1 inches above the ground not having a ladder installed.
Recent events (1)
- — Z (S) $3803
1926.451 G04 I
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $3803.00
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. (a) Backside of the school left scaffold - On or about November 2, 2016 three employees were exposed to a fall hazard due to a scaffold 16 feet 4 inches above the ground without having guardrails on all open sides. (b) Backside of the school right scaffold - On or about November 2, 2016 employees were exposed to a fall hazard while working on a scaffold 21 feet 1 inches above the ground without having guardrails on all open sides.
Recent events (1)
- — Z (S) $3803
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. (a ) Backside of the school right scaffold - On or about November 2, 2016 employees were exposed to a fall hazard due to scaffolds not being inspected prior to use. This scaffold 1) was not fully decked or planked 2) had no ladder installed 3) did not have guardrails on all open sides 4) had no ties to the building although it was over 20 feet high.
Recent events (1)
- — Z (O) $0
More inspections at FOUR SEASONS MASONRY
RIVER FOREST, IL—2025-03-18
FOUR SEASONS MASONRY
JACKSON, MS—2017-04-13 00:00:00
FOUR SEASONS MASONRY
JACKSON, MS—2010-06-04 00:00:00
FOUR SEASONS MASONRY
JACKSON, MS—2010-01-12 00:00:00
FOUR SEASONS MASONRY
View FOUR SEASONS MASONRY's full OSHA safety record →
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in MS
LAUREL, MS—2026-07-01