Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DESIGNER GUTTER COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DESIGNER GUTTER COMPANY in 357 2ND ST N, SAINT PETERSBURG, FL 33701 (NAICS 237110). OSHA activity number 341895068.

Watch Designer Gutter Company — free Get an email when a new federal OSHA severe-injury report for Designer Gutter Company is published. One employer, no account, unsubscribe in one click.
Site address
357 2ND ST N
City
SAINT PETERSBURG
State
FL
ZIP
33701
Mailing
PO BOX 30, OLDSMAR, FL 34677
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
10
Ownership type
A

7 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $2662.00 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  a) At the jobsite, an employee was exposed to an electrical hazard of 7,200 volts while carrying 30 foot aluminum gutters up the ladder and positioning them on a roof with power lines 12 feet 4 inches from the roof edge and were not de-energizing or effectively guarded or insulated. This violation was discovered on or about November 4, 2016.
Recent events (2)
  • — I (S) $2662.1
  • — Z (S) $3803

1926.416 A03

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(a)(3): Employer did not advise employees of the location of energized electrical power circuits, the hazards involved, and the protective measures to be taken:  a) At the jobsite, an employee was exposed to an electrical hazard of 7,200 volts while carrying 30 foot aluminum gutters up the ladder and positioning them on a roof with power lines 12 feet 4 inches away. This violation was discovered on or about November 4, 2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1901.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) At the jobsite, employees were exposed to a 11' 10" fall hazard, in that, fall protection was not used while measuring and installing gutters on the roof. Violation discovered on or about November 4, 2016.
Recent events (2)
  • — I (S) $1901.2
  • — Z (S) $2716

1926.503 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:  a. At the jobsite, employees were exposed to a 11' 10" fall hazard, in that, a fall protection training program was not adequate for employees who were exposed to fall hazards. Employees were trained that they only needed to wear fall protection when slope was 6:12 or greater. Violation discovered on or about November 4, 2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $2662.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) At the jobsite, employees were exposed to a 26 foot fall hazard, in that, an extension ladder was used by the employees to access and descend from the roof, extended approximately 12 inches above the landing surface. This violation was discovered on or about January 31, 2017.
Recent events (2)
  • — I (S) $2662.1
  • — Z (S) $3803

1926.1060 A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards.  a) At the jobsite, an employee was exposed to a fall hazard due to not having adequate training on ladders. Employees had not been trained to extend the ladder 3 feet above the landing surface. This violation was discovered on or about November 4, 2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B22

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $2662.00 Reduced
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall:  a) At the jobsite, an employee was exposed to a fall hazard while carrying 30 foot aluminum gutters up the ladder. This violation was discovered on or about November 4, 2016.
Recent events (2)
  • — I (S) $2662.1
  • — Z (S) $3803

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341895068.